Western Australia variation · NCC 2025 Volume One

WA F9D2 Required size of vertical downpipes

WA Part F9 Changes to AS/NZS 3500.3-2021

Open on NCC Online ↗

Delete clause F9D2 and insert WA F9D2 as follows:

Delete Table 3.5.2 of AS/NZS 3500.3-2021 and replace with the following:

Insert WA table (F9D2) F9D2 as follows:

WA Table F9D2: Table 3.5.2 – Eaves gutter – Required size of vertical downpipe

Effective cross-sectional area of an eaves gutter (Ae)a, b

Internal size of vertical down pipe, mm

Gradient

Cross-section

1:500 and steeper

Flatter than 1:500

Circular

Rectangle or square

3500

4700

65

65 x 50 or 95 x 45

4200

5600

75

65 x 50 or 95 x 45

4600

6200

75

75 x 50 or 95 x 45

4800

6400

80

75 x 50 or 95 x 45

5200

7000

80

100 x 50 or 95 x 45

5900

7900

85

100 x 50

6400

8600

90

100 x 50

6600

8900

90

75 x 70

6700

9000

100

75 x 70

8200

11000

100

100 x 75

9600

12900

125

100 x 75

12800

17100

125

100 x 100

12800

17200

150

100 x 100

16000

21500

150

125 x 100

18400

24700

150

150 x 100

19200

25800

-

150 x 100

20000

26800

-

125 x 125

Table Notes

The effective cross-sectional area shall be obtained from Figures 3.5.4(A) and 3.5.4(B) to the nearest 100 mm2.

Refer to AS/NZS 2179.1.

New in NCC 2025. No WA F9D2 in NCC 2022 Volume One; it may have moved or been renumbered.