Housing Provisions clause · ABCB Housing Provisions 2022

10.2.16 Hob construction

Part 10.2 Wet area waterproofing

Open 10.2.16 on NCC Online ↗

(1) Hobs must be constructed of—

masonry; or

concrete; or

autoclaved aerated concrete; or

extruded polyurethane foam,

in accordance with Figure 10.2.16.

(2) All gaps, joints and intersections of the hob substrate must be made flush before application of a membrane.

(3) Hobs must be adequately secured to the floor and sealed against the wall prior to applying a membrane.

(4) Timber must not be used for hob construction.

Figure 10.2.16 Typical hob construction — internal membrane

Figure Notes

For shower screen positioning, see 10.2.32.

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 10.2.16.

Clauses referred to

Defined terms used