Housing Provisions clause · ABCB Housing Provisions 2022

10.2.4 Areas adjacent to baths and spas without showers

Part 10.2 Wet area waterproofing · NCC 2019: Table 3.8.1.1

Open 10.2.4 on NCC Online ↗

(1) For areas adjacent to all baths and spas, the following applies:

For concrete, compressed fibre-cement and fibre-cement sheet flooring, the floor of the room must be water resistant.

For timber floors including particleboard, plywood and other timber based flooring materials, the floor of the room must be waterproof.

Tap and spout penetrations must be waterproof where they occur in horizontal surfaces.

(2) For areas adjacent to non-freestanding baths and spas, the following applies:

Walls must be water resistant (see Figure 10.2.4a and Figure 10.2.4b)—

to a height of not less than 150 mm above the vessel, for the extent of the vessel, where the vessel is within 75 mm of a wall; and

for all exposed surfaces below vessel lip.

Wall junctions and joints must be water resistant within 150 mm above a vessel for the extent of the vessel.

Wall/floor junctions must be waterproof for the extent of the vessel (see Figure 10.2.4a and Figure 10.2.4b).

(3) For inserted baths and spas, the following applies:

For floors and horizontal surfaces:

Any shelf area adjoining the bath or spa must be waterproof and include a waterstop under the vessel lip.

There are no requirements for the floor under a bath or spa.

For walls:

Waterproof to not less than 150 mm above the lip of a bath or spa.

There are no requirements for the floor under a bath or spa.

For wall junctions and joints, the following applies:

Waterproof junctions within 150 mm of a bath or spa.

There are no requirements for junctions and joints in walls beneath the lip of a bath or spa.

Tap and spout penetrations must be waterproof where they occur in horizontal surfaces.

Figure 10.2.4a Areas adjacent to baths and spas without showers for concrete, compressed fibre-cement and fibre-cement sheet flooring

Figure 10.2.4b Areas adjacent to baths and spas without showers for timber floors including particleboard, plywood and other floor materials

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 10.2.4.