Housing Provisions clause · ABCB Housing Provisions 2022

11.3.8 Protection of openable windows – rooms other than bedrooms

Part 11.3 Barriers and handrails · NCC 2019: 3.9.2.7

Open 11.3.8 on NCC Online ↗

(1) A window opening in a room other than a bedroom must be provided with protection where the floor below the window is 4 m or more above the surface beneath.

(2) The openable part of the window covered by (1) must be protected with a barrier with a height of not less than 865 mm above the floor.

(3) A barrier required by (2) must not—

permit a 125 mm sphere to pass through it; and

have any horizontal or near horizontal elements between 150 mm and 760 mm above the floor that facilitate climbing.

Notes

Figure 11.3.8 illustrates requirements of this provision.

Figure 11.3.8 Protection of openable windows — rooms other than bedrooms

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 11.3.8.

Defined terms used