Housing Provisions clause · ABCB Housing Provisions 2022

13.5.2 Ceiling fans

Part 13.5 Ceiling fans · NCC 2019: 3.12.4.3

Open 13.5.2 on NCC Online ↗
Varied in NT. Check the variation for your state.

Ceiling fans must be installed in accordance with Table 13.5.2 in—

climate zones 1, 2 and 3; and

climate zone 5 in New South Wales and Queensland.

Table 13.5.2 Minimum ceiling fan requirements in climate zones 1, 2, 3 and 5

Size of room (m²)

Minimum number and diameter (mm) of ceiling fans required in a bedroom in climate zones 1, 2 and 3

Minimum number and diameter (mm) of ceiling fans required in a habitable room other than a bedroom in climate zones 1, 2, 3 and 5 (NSW and Qld)

<15

1 x 900

1 x 900

≥15<20

1 x 1200

1 x 1200

≥20<25

1 x 1200

1 x 1400

≥25<30

1 x 1400

2 x 1200

≥30<45

1 x 1400

2 x 1400

≥45<50

2 x 1400

3 x 1200

≥50

2 x 1400

3 x 1400

Tables

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 13.5.2.

State and territory variations all clauses side by side →

Defined terms used