Housing Provisions clause · ABCB Housing Provisions 2022

4.2.18 Footings for fireplaces on Class A and S sites

Part 4.2 Footings, slabs and associated elements · NCC 2019: 3.2.5.5

Open 4.2.18 on NCC Online ↗

(1) Fireplaces on Class A and S sites must be supported on a pad footing—

150 mm thick for single storey (one trafficable floor and a wall height not more than 4.2 m) construction; and

200 mm thick for 2 storey (two trafficable floors and a wall height not more than 8 m) construction; and

reinforced top and bottom with SL72 mesh; and

extending 300 mm past the edges of the masonry except for any edge flush with the outer wall.

(2) The pad footing must form an integral part of the slab.

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 4.2.18.