Housing Provisions clause · ABCB Housing Provisions 2022

6.3.9 Corrosion protection

Part 6.3 Structural steel members · NCC 2019: 3.4.4.4

Open 6.3.9 on NCC Online ↗

Structural steel members that are not built in to a masonry wall must—

be protected against corrosion in accordance with Tables 6.3.9a, 6.3.9b and 6.3.9c; and

where a paint finish is applied to the surface, be free from rust; and

where zinc coatings are applied to the surface, be provided with a barrier coat to prevent domestic enamels from peeling; and

when cut or welded on-site, have those areas and any other areas of damage to protective coatings comply with (a).

Table 6.3.9a Minimum protective coatings for structural steel members

Environment

Location

Minimum protective coating

Option 1 (hot dip galvanising)

Option 2 (duplex system). See Table 6.3.9c

Option 3 (paint). See Table 6.3.9b

Low (mild steel corrosion rate 1.3 to 25 μm/year

Typically remote inland areas or more than 1 km from sheltered bays

HDG75

–

ACL2, ACC2, IZS1, PUR2A

Medium (mild steel corrosion rate 25 to 50 μm/year)

Typically more than 1 km from breaking surf or aggressive industrial areas or more than 50 m from sheltered bays

HDG225

–

ACL3, ACC4, ACC5, IZS1, PUR3, PUR4

High (mild steel corrosion rate 50 to 80 μm/year)

Typically more than 200 m from breaking surf or aggressive industrial areas or within 50 m from sheltered bays

HDG450

HDG150 (5 years) 4D (10-15 years) or HDG300 (10 years) 2D (5-10 years)

ACC6, IZS3, PUR5

Very High (mild steel corrosion rate 80 to 200 μm/year)

Typically extends from 100 m inland from breaking surf to 200 m inland from breaking surf, or within 200 m of aggressive industrial areas and within 100 m of breaking surf.

HDG900

HDG300 (5 years) 5D (10-15 years) or HDG600 (10 years) 4D (5-10 years)

ACC6 (C5-M only), PUR5

Table Notes

Hot dip galvanising and duplex systems must be in accordance with AS 2312.2. Paint systems must be in accordance with AS 2312.1.

Table 6.3.9b Paint coating system specification

AS 2312.1 system

Surface preparation

1st coat

2nd coat

3rd coat

Total DFT

Type of paint

DFT

Type of paint

DFT

Type of paint

DFT

ACC2

Sa 2.5

Epoxy primer

75

Acrylic (2 pack)

50

–

–

125

ACC4

Sa 2.5

Epoxy primer

75

High build epoxy

125

Acrylic (2 pack)

50

250

ACC5

Sa 2.5

Zinc rich primer

75

High build epoxy

125

Acrylic (2 pack)

50

250

ACC6

Sa 2.5

Zinc rich primer

75

High build epoxy

200

Acrylic (2 pack)

50

325

ACL2

Sa 2.5

Zinc rich primer

75

Acrylic latex

40

Acrylic latex

40

155

ACL3

Sa 2.5

Zinc rich primer

75

High build epoxy

125

Acrylic latex

40

240

IZS1

Sa 2.5

Inorganic zinc silicate

75

–

–

–

–

75

IZS3

Sa 2.5

Inorganic zinc silicate

125

–

–

–

–

125

PUR2A

Sa 2.5

Zinc rich primer

75

High build polyurethane

75

–

–

150

PUR3

Sa 2.5

Epoxy primer

75

High build epoxy

125

Polyurethane gloss

50

250

PUR4

Sa 2.5

Zinc rich primer

75

High build epoxy

125

Polyurethane gloss

50

250

PUR5

Sa 2.5

Zinc rich primer

75

High build epoxy

200

Polyurethane gloss

50

325

Table Notes

DFT refers to dry film thickness, measured in μm.

Table 6.3.9c Duplex coating system specification

AS 2312.2 duplex system

Surface preparation

1st coat

2nd coat

3rd coat

Total DFT

Type of paint

DFT

Type of paint

DFT

Type of paint

DFT

2D

Degrease, wash and dry, sweep blast clean

Epoxy primer (2 pack) inhibitive

75

Polyurethane or acrylic gloss (2 pack)

100

–

–

175

4D

Degrease, wash and dry, sweep blast clean

High-build epoxy (2 pack)

250

Polyurethane or acrylic gloss (2 pack)

100

–

–

350

5D

Degrease, wash and dry, sweep blast clean

Epoxy primer (2 pack) inhibitive

75

High-build epoxy (2 pack)

225

Polyurethane or acrylic gloss (2 pack)

100

400

Table Notes

DFT refers to dry film thickness, measured in μm.

Notes

Clause 3.4.4.4 and Table 3.4.4.7 from NCC Volume Two 2019 (Amendment 1) may be used in place of 6.3.9 and Tables 6.3.9a, 6.3.9b and 6.3.9c until 1 May 2024.

Tables

Changed in NCC 2025. See ABCB Housing Provisions 2025 6.3.9, or show what changed.

Structural steel members that are not built in to a … Notes DFT refers to dry film thickness, measured in μm. Notes Clause 3.4.4.4 and Table 3.4.4.7 from NCC Volume Two 2019 (Amendment 1) may be used in place of 6.3.9 and Tables 6.3.9a, 6.3.9b and 6.3.9c until 1 May 2024.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used