7.2.4 Maximum spans
Part 7.2 Sheet roofing · NCC 2019: 3.5.1.4
Metal sheet roofing must comply with the maximum span between roofing supports in accordance with Table 7.2.4 and Figure 7.2.4.
Table 7.2.4 Maximum roofing spans between supports
Sheet roofing profile
Sheet roofing base metal thickness (mm)
Max. end span (mm) Note 1
Max. internal span (mm) Note 1
Corrugated
0.42
900
1200
Close pitched trapezoidal
0.42
1800
2400
Trapezoidal
0.42
1300
1700
Concealed fasteners — narrow sheet
0.42
1750
2100
Concealed fasteners — wide sheet
0.48
1800
2100
Table Notes
Refer to Figure 7.2.4 for determination of end span and internal spans.
Thermal expansion - Maximum sheet run for pierced fixed metal roofing profiles must be not greater than 25 m when measured between the fasteners at the ends of the sheet.
Figure 7.2.4 Maximum spans for roofing between supports