Housing Provisions clause · ABCB Housing Provisions 2025

7.2.4 Maximum spans

Part 7.2 Sheet roofing · NCC 2019: 3.5.1.4

Open 7.2.4 on NCC Online ↗

Metal sheet roofing must comply with the maximum span between roofing supports in accordance with Table 7.2.4 and Figure 7.2.4.

Table 7.2.4 Maximum roofing spans between supports

Sheet roofing profile

Sheet roofing base metal thickness (mm)

Max. end span (mm) Note 1

Max. internal span (mm) Note 1

Corrugated

0.42

900

1200

Close pitched trapezoidal

0.42

1800

2400

Trapezoidal

0.42

1300

1700

Concealed fasteners — narrow sheet

0.42

1750

2100

Concealed fasteners — wide sheet

0.48

1800

2100

Table Notes

Refer to Figure 7.2.4 for determination of end span and internal spans.

Thermal expansion - Maximum sheet run for pierced fixed metal roofing profiles must be not greater than 25 m when measured between the fasteners at the ends of the sheet.

Figure 7.2.4 Maximum spans for roofing between supports

Tables

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 7.2.4.