Housing Provisions clause · ABCB Housing Provisions 2022

8.2.2 Installation of windows

Part 8.2 Windows and external glazed doors

Open 8.2.2 on NCC Online ↗

Windows must be installed in accordance with the following:

Structural building loads must not be transferred to the window assembly.

A minimum 10 mm gap must be provided between the top of the window assembly and any loadbearing framing or masonry wall element.

The requirements of (b) may be increased where necessary to allow for frame settlement over wide openings.

Packing, if provided between each window assembly and the frame, must be—

located along each side and bottom; and

fixed to ensure the sides and bottom of the window assembly remain straight; and

clear of any flashing material.

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 8.2.2.

Defined terms used