8.4.7 Visibility of glazing
Part 8.4 Glazing human impact · NCC 2019: 3.6.4.6
(1) If the presence of glazing in a door, side panel or panel capable of being mistaken for a doorway or opening is not made apparent in accordance with 8.4.4(2)(c), the glass must be marked to make it readily visible in accordance with (2).
(2) Marking must be in the form of an opaque band not less than 20 mm in height located so that—
the upper edge is not less than 700 mm above the floor; and
the lower edge is not more than 1.2 m above the floor.
(3) A band or marking is not required where any of the following applies:
The height of the glazing is not more than 1 m in any part.
The width of the glazing panel is not more than 500 mm in any part.
There is no glazing within 500 mm of the floor.
The glazing is provided with not less than one fixed glazing bar which must—
be firmly attached to the stiles to locate and protect each face of the glass; and
be located with its upper edge not less than 500 mm and its bottom edge not more than 1 m above the floor; and
have a face width not less than 40 mm.