ABCB Housing Provisions 2022
Part 8.4 Glazing human impact
10 clauses · Open on NCC Online ↗
- 8.4.1 ApplicationPart 8.4 applies subject to the limitations set out in H1D8(1). (2) Part 8.4 need not be complied with if H1D8(3) is complied with. (3) The…
- Table 8.4.2 Maximum areas of glazing material for framed glass doors, framed glass side panels and other framed glazed panelsType of glass | Minimum nominal thickness (mm) | Maximum area of pane (m2) Patterned or clear monolithic annealed glass | 5 | 0.3 Patterned or clear…
- 8.4.2 Doors, side panels and other framed glazed panelsGlass in doors must be Grade A safety glazing material in accordance with Table 8.4.2 and Figure 8.4.2, except that— unframed doors, other than…
- 8.4.3 Door side panelsAll framed glass (except leadlight panels) in side panels with their nearest vertical sight line less than 300 mm from the nearest edge of the…
- 8.4.4 Full height framed glazed panelsA glazed panel located in a building so that it is capable of being mistaken for an unobstructed opening must be glazed with Grade A safety glazing…
- 8.4.5 Glazed panels, other than doors or side panels, on the perimeter of roomsAll framed glazing where the lowest sight line of the glazing panel is less than 500 mm from the highest abutting finished floor level (see Figure…
- Table 8.4.6 Maximum areas of safety glazing materials for shower doors, shower screens and bath enclosuresType of glass | Standard nominal thickness (mm) | Maximum area of pane (m2) | Area (Figure 8.4.6) Safety organic coated glass | 3 | 1 | A, B, C, D…
- 8.4.6 Kitchen, bathroom, ensuite, spa room and splash-back glazingAll glazing in kitchens, bathrooms, ensuites, spa rooms or the like, including shower doors, shower screens, bath enclosures, and associated windows…
- 8.4.7 Visibility of glazingIf the presence of glazing in a door, side panel or panel capable of being mistaken for a doorway or opening is not made apparent in accordance with…
- 8.4.8 Identification of safety glassAll safety glazing material in Tables 8.4.2 and Table 8.4.6 installed in accordance with this Part must comply with the following: Safety glass must…