9.2.2 Measurement of distances
Part 9.2 Fire separation of external walls · NCC 2019: 3.7.2.3
(1) The distance from any point on an external wall of a building to an allotment boundary or another building is the distance to that point measured along a line at right angles from the allotment boundary or external wall of the other building which intersects that point without being obstructed by a wall complying with 9.2.3.
(2) Where a wall within a specified distance is required to comply with 9.2.3, only that part of the wall (including any openings) within the specified distance need be constructed in that manner (see Figure 9.2.2a, Figure 9.2.2b and Figure 9.2.2c).
(3) Where the distance measured is between attached or detached buildings of different heights, the distance must be taken from the external wall with the highest elevation measured at right angles to a point that intersects the nearest part of a vertical projection above the adjacent building, excluding any eave overhang (see Figure 9.2.2d and Figure 9.2.2e).
Figure 9.2.2a Walls at right angles to the boundary
Figure Notes
No protection required for the wall at right angles or more to the boundary.
For protection of encroachments refer to 9.2.9.
Figure 9.2.2b Measurement of distances — Full wall protection (Plan view)
Figure Notes
Setback distance is measured at right angles to the boundary.
Figure 9.2.2c Measurement of distances — Part walls protection (Plan view)
Figure Notes
Setback distance is measured at right angles to the boundary.
Figure 9.2.2d Measurement of distance — Buildings of different heights — Class 1 buildings on same allotment
Figure 9.2.2e Measurement of distance — Buildings of different heights — Attached Class 1 buildings on same allotment