New South Wales variation · ABCB Housing Provisions 2022

NSW 13.2.3 Roofs and ceilings

Part 13.2 Building fabric · varies 13.2.3 Roofs and ceilings

Open on NCC Online ↗

Delete clause 13.2.3 and insert NSW 13.2.3 as follows:

(1) A roof that—

has metal sheet roofing directly fixed to metal purlins, metal rafters or metal battens; and

does not have a ceiling lining or has a ceiling lining fixed directly to those metal purlins, metal rafters or metal battens,

must have a thermal break, consisting of a material with an R-Value of greater than or equal to 0.2, installed between the metal sheet roofing and its supporting metal purlins, metal rafters or metal battens.

(2) (1) does not apply to roofs constructed using insulated sandwich panels.

Not in NCC 2025. No NSW 13.2.3 in ABCB Housing Provisions 2025.

The national clause

Other states and territories