Table 13.2.5o Lightweight wall – minimum insulation R-Value: climate zone 8
| SA | Overhang (mm) | Wall height (m) | |||
|---|---|---|---|---|---|
| ≤ 2.4 | > 2.4 to ≤ 2.7 | > 2.7 to ≤ 3.0 | > 3.0 to ≤ 3.6 | ||
| ≤ 0.35 | 0 | 1.5 | 2.0 | 2.0 | X |
| > 0 to ≤ 300 | 2.0 | 2.0 | 2.4 | X | |
| > 300 to ≤ 450 | X | 2.4 | 2.4 | X | |
| > 450 to ≤ 600 | X | X | 2.5 | X | |
| > 600 to ≤ 900 | X | X | X | X | |
| > 900 to ≤ 1200 | X | X | X | X | |
| > 0.35 to ≤ 0.5 | 0 | 1.5 | 1.5 | 2.0 | 2.4 |
| > 0 to ≤ 300 | 2.0 | 2.0 | 2.0 | 2.5 | |
| > 300 to ≤ 450 | 2.5 | 2.0 | 2.4 | 2.5 | |
| > 450 to ≤ 600 | X | 2.5 | 2.4 | X | |
| > 600 to ≤ 900 | X | X | X | X | |
| > 900 to ≤ 1200 | X | X | X | X | |
| > 0.5 to ≤ 0.7 | 0 | 1.5 | 1.5 | 2.0 | 2.7 |
| > 0 to ≤ 300 | 2.0 | 2.0 | 2.0 | 2.7 | |
| > 300 to ≤ 450 | 2.7 | 2.0 | 2.0 | 2.7 | |
| > 450 to ≤ 600 | X | 2.7 | 2.5 | 2.5 | |
| > 600 to ≤ 900 | X | X | X | X | |
| > 900 to ≤ 1200 | X | X | X | X | |
| > 0.7 to ≤ 0.85 | 0 | 1.5 | 1.5 | 1.5 | 2.0 |
| > 0 to ≤ 300 | 2.0 | 1.5 | 2.0 | 2.4 | |
| > 300 to ≤ 450 | 2.4 | 2.0 | 2.0 | 2.4 | |
| > 450 to ≤ 600 | X | 2.4 | 2.0 | 2.4 | |
| > 600 to ≤ 900 | X | X | X | X | |
| > 900 to ≤ 1200 | X | X | X | X |
Table Notes
SA = solar absorptance.
R-Values listed are for the labelled, declared R-Value of insulation.
X = not permitted.
This Table shows wall heights for single storey dwellings. For two storey (or more) dwellings with a wall height up to 2.4 m, add R0.5 to the R-Values given in this Table. For two storey (or more) dwellings with a wall height greater than 2.4 m, add R1.0. In both cases, the maximum insulation level must be not more than R2.7, or R3.1 if there is a reflective airspace.
Table for 13.2.5 External walls
Changed in NCC 2025. See ABCB Housing Provisions 2025 Table 13.2.5o, or show what changed.
SA | Overhang (mm) | Wall height (m) ≤ 2.4 … than R2.7, or R3.1 if there is a reflective airspace. Where an overhang of > 600 mm is used, the values for > 450 to ≤ 600 apply provided no more than 15% of the total opaque wall area of the dwelling (excluding windows/doors) is covered by overhangs > 600 mm.
Removed words are struck through; added words are highlighted. Comparison of the text only.