Table · ABCB Housing Provisions 2022

Table 13.3.2aa Winter solar heat gain factor: climate zone 3

Part 13.3 External glazing

Open Table 13.3.2aa on NCC Online ↗
Type of factorFactor for a floor in direct contact with the groundFactor for a suspended floor
Room factor (RW) for a bedroom and a room which is not a conditioned space0.261.00
Bedroom solar heat gain factor (BSW)0.790.50
Level factor (LW) for all levels above the lowest floor1.191.30
Frame factor (FW) for frames with a solar absorptance of ≤ 0.400.970.97
Frame factor (FW) for frames with a solar absorptance of > 0.40 to < 0.681.001.00
Frame factor (FW) for frames with a solar absorptance of ≥ 0.681.041.04
Floor factor (for tiled or vinyl covered floor) (HW)1.15Not applicable

Table Notes

Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2aa.

Defined terms used