ABCB Housing Provisions 2022
Part 13.3 External glazing
62 clauses · Open on NCC Online ↗
- 13.3.1 Application of Part 13.3 NTThis Part applies to— a Class 1 building; and a Class 10a building with a conditioned space. (2) Part 13.3 must be applied as directed in H6D2(1)(b).
- Table 13.3.2a Maximum conductance to solar heat gain ratio (CU/CSHGC)Climate zone | Floor in direct contact with the ground | Suspended floor 2 | 9.60 | 9.37 3 | 19.10 | 14.75 4 | 10.25 | 8.04 5 (lightweight wall) |…
- Table 13.3.2b Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 2P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.49 | 1.48 | 1.08 | 0.47 | 0.41 | 0.46 | 1.05 | 1.44…
- Table 13.3.2c Orientation sector winter exposure factor (EW) — suspended floor: climate zone 2P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.67 | 1.36 | 1.20 | 0.52 | 0.19 | 0.85 | 1.18 | 1.51…
- Table 13.3.2d Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 3P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.36 | 1.16 | 0.75 | 0.38 | 0.38 | 0.43 | 1.05 | 1.41…
- Table 13.3.2e Orientation sector winter exposure factor (EW) — suspended floor: climate zone 3P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.92 | 1.29 | 0.97 | 0.82 | 0.75 | 1.07 | 1.24 | 1.69…
- Table 13.3.2f Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 4P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.48 | 1.40 | 0.91 | 0.47 | 0.46 | 0.51 | 1.11 | 1.57…
- Table 13.3.2g Orientation sector winter exposure factor (EW) — suspended floor: climate zone 4P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.38 | 1.12 | 1.00 | 0.71 | 0.56 | 0.87 | 1.02 | 1.26…
- Table 13.3.2h Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 5 (lightweight wall)P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.61 | 1.55 | 1.00 | 0.49 | 0.44 | 0.47 | 1.02 | 1.58…
- Table 13.3.2i Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 5 (concrete or masonry wall)P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.61 | 1.55 | 1.00 | 0.43 | 0.33 | 0.43 | 1.11 | 1.66…
- Table 13.3.2j Orientation sector winter exposure factor (EW) — suspended floor: climate zone 5 (lightweight wall)P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.61 | 1.20 | 1.00 | 0.65 | 0.48 | 0.95 | 1.19 | 1.47…
- Table 13.3.2k Orientation sector winter exposure factor (EW) — suspended floor: climate zone 5 (concrete or masonry wall)P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.71 | 1.24 | 1.00 | 0.63 | 0.44 | 0.94 | 1.19 | 1.54…
- Table 13.3.2l Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 6P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.52 | 1.44 | 1.28 | 0.77 | 0.77 | 0.74 | 1.32 | 1.45…
- Table 13.3.2m Orientation sector winter exposure factor (EW) — suspended floor: climate zone 6P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.62 | 1.31 | 1.16 | 0.72 | 0.49 | 0.90 | 1.10 | 1.44…
- Table 13.3.2n Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 7P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.87 | 1.92 | 1.20 | 0.52 | 0.46 | 0.53 | 1.13 | 1.80…
- Table 13.3.2o Orientation sector winter exposure factor (EW) — suspended floor: climate zone 7P/H | North | North east | East | South east | South | South west | West | North east 0.00 | 1.87 | 1.43 | 1.20 | 0.75 | 0.53 | 0.93 | 1.13 | 1.62…
- Table 13.3.2p Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 8P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 2.30 | 2.40 | 1.66 | 0.67 | 0.36 | 0.65 | 1.59 | 2.30…
- Table 13.3.2q Orientation sector winter exposure factor (EW) — suspended floor — climate zone 8P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.39 | 1.27 | 1.22 | 0.80 | 0.59 | 0.90 | 1.05 | 1.28…
- Table 13.3.2r Bedroom conductance factor (BC)Climate zone | Floor in direct contact with the ground | Suspended floor 2 | 0.90 | 0.70 3 | 1.11 | 0.70 4 | 1.10 | 0.95 5 (lightweight or masonry…
- Table 13.3.2s Orientation sector conductance factor (OC): climate zone 2Floor type | North | North east | East | South east | South | South west | West | North east Floor in direct contact with the ground | 1.11 | 0.97 |…
- Table 13.3.2t Orientation sector conductance factor (OC): climate zone 3Floor type | North | North east | East | South east | South | South west | West | North west Floor in direct contact with the ground | 1.25 | 1.08 |…
- Table 13.3.2u Orientation sector conductance factor (OC): climate zone 4Floor type | North | North east | East | South east | South | South west | West | North west Floor in direct contact with the ground | 1.15 | 0.93 |…
- Table 13.3.2v Orientation sector conductance factor (OC): climate zone 5Wall construction | Floor type | North | North east | East | South east | South | South west | West | North west Lightweight or masonry veneer |…
- Table 13.3.2w Orientation sector conductance factor (OC): climate zone 6Floor type | North | North east | East | South east | South | South west | West | North west Floor in direct contact with the ground | 1.05 | 0.98 |…
- Table 13.3.2x Orientation sector conductance factor (OC): climate zone 7Floor type | North | North east | East | South east | South | South west | West | North west Floor in direct contact with the ground | 1.30 | 1.05 |…
- Table 13.3.2y Orientation sector conductance factor (OC): climate zone 8Floor type | North | North east | East | South east | South | South west | West | North west Floor in direct contact with the ground | 1.30 | 1.10 |…
- Table 13.3.2z Winter solar heat gain factors: climate zone 2Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RW) for a bedroom and a room which…
- Table 13.3.2aa Winter solar heat gain factor: climate zone 3Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RW) for a bedroom and a room which…
- Table 13.3.2ab Winter solar heat gain factors: climate zone 4Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RW) for a bedroom and a room which…
- Table 13.3.2ac Winter solar heat gain factors: climate zone 5 — lightweight or masonry veneer wallType of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RW) for a bedroom and a room which…
- Table 13.3.2ad Winter solar heat gain factors: climate zone 5 — concrete or masonry wallType of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RW) for a bedroom and a room which…
- Table 13.3.2ae Winter solar heat gain factors: climate zone 6Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RW) for a bedroom and a room which…
- Table 13.3.2af Winter solar heat gain factors: climate zone 7Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RW) for a bedroom and a room which…
- Table 13.3.2ag Winter solar heat gain factors: climate zone 8Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RW) for a bedroom or a which is…
- 13.3.2 External glazing — winter NTIn climate zones 2 to 8, the ratio of the conductance (Cu) and solar heat gain (CSHGC) of the glazing in each storey, including any mezzanine, must—…
- Table 13.3.3a Constant for solar heat gain coefficient (CSHGC): climate zones 1 to 7Floor type | Ventilation opening area | Climate zone 1 | 2 | 3 | 4 | 5 (lightweight wall) | 5 (concrete or brick wall) | 6 | 7 Floor in direct…
- Table 13.3.3b Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 1P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.35 | 1.64 | 1.69 | 1.62 | 1.13 | 1.65 | 1.72 | 1.66…
- Table 13.3.3c Orientation sector summer exposure factor (ES) — suspended floor: climate zone 1P/H | North | North east | East | South East | South | South west | West | North west 0.00 | 0.61 | 0.96 | 1.43 | 1.19 | 0.70 | 1.15 | 1.32 | 0.92…
- Table 13.3.3d Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 2P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.59 | 1.08 | 1.50 | 0.93 | 0.40 | 1.05 | 1.78 | 1.19…
- Table 13.3.3e Orientation sector summer exposure factor (ES) — suspended floor: climate zone 2P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.43 | 0.81 | 1.16 | 0.75 | 0.36 | 1.06 | 1.88 | 1.11…
- Table 13.3.3f Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 3P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.95 | 1.51 | 1.70 | 1.53 | 0.92 | 1.45 | 1.50 | 1.41…
- Table 13.3.3g Orientation sector summer exposure factor (ES) — suspended floor: climate zone 3P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.78 | 1.30 | 1.56 | 1.36 | 0.79 | 1.16 | 1.09 | 1.11…
- Table 13.3.3h Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 4P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.83 | 1.13 | 1.05 | 0.68 | 0.31 | 0.99 | 1.90 | 1.46…
- Table 13.3.3i Orientation sector summer exposure factor (ES) — suspended floor: climate zone 4P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.79 | 1.13 | 1.12 | 0.68 | 0.29 | 0.64 | 1.05 | 1.06…
- Table 13.3.3j Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 5 (lightweight or masonry veneer wall)P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.62 | 0.79 | 0.83 | 0.67 | 0.48 | 1.04 | 1.69 | 1.19…
- Table 13.3.3k Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 5 (concrete or masonry wall)P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.98 | 1.14 | 1.07 | 0.60 | 0.24 | 0.78 | 1.50 | 1.36…
- Table 13.3.3l Orientation sector summer exposure factor (ES) — suspended floor: climate zone 5 (lightweight or masonry veneer wall)P/H | North | North east | East | South East | South | South west | West | North west 0.00 | 0.67 | 0.93 | 1.05 | 0.61 | 0.27 | 0.67 | 1.16 | 0.99…
- Table 13.3.3m Orientation sector summer exposure factor (ES) — suspended floor: climate zone 5 (concrete or masonry wall)P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.82 | 1.04 | 1.07 | 0.72 | 0.41 | 0.78 | 1.17 | 1.10…
- Table 13.3.3n Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 6P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.01 | 1.19 | 1.15 | 0.78 | 0.49 | 1.10 | 1.82 | 1.55…
- Table 13.3.3o Orientation sector summer exposure factor (ES) — suspended floor: climate zone 6P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 0.88 | 1.05 | 1.04 | 0.57 | 0.24 | 0.96 | 2.00 | 1.54…
- Table 13.3.3p Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 7P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.06 | 1.30 | 1.36 | 1.09 | 0.77 | 1.11 | 1.49 | 1.39…
- Table 13.3.3q Orientation sector summer exposure factor (ES) — suspended floor: climate zone 7P/H | North | North east | East | South east | South | South west | West | North west 0.00 | 1.15 | 1.17 | 0.97 | 0.75 | 0.51 | 0.77 | 1.07 | 1.24…
- Table 13.3.3r Summer solar heat gain factors: climate zone 1Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RS) for a bedroom and a room which…
- Table 13.3.3s Summer solar heat gain factors: climate zone 2Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RS) for a bedroom and a room which…
- Table 13.3.3t Summer solar heat gain factors: climate zone 3Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RS) for a bedroom and a room which…
- Table 13.3.3u Summer solar heat gain factors: climate zone 4Type factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RS) for a bedroom and a room which is…
- Table 13.3.3v Summer solar heat gain factors: climate zone 5 (lightweight or masonry veneer wall)Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RS) for a bedroom and a room which…
- Table 13.3.3w Summer solar heat gain factors: climate zone 5 (concrete or masonry wall)Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RS) for a bedroom and a room which…
- Table 13.3.3x Summer solar heat gain factors: climate zone 6Type of factor | Factor for a floor in direct contact with the ground | Factor for suspended floor Room factor (RS) for a bedroom and a room which…
- Table 13.3.3y Summer solar heat gain factors: climate zone 7Type of factor | Factor for a floor in direct contact with the ground | Factor for a suspended floor Room factor (RS) for a bedroom and a room which…
- 13.3.3 External glazing — summer NTIn climate zones 1 to 7, the aggregate solar heat gain of the glazing in each storey of a building, including any mezzanine, must— not exceed the…
- 13.3.4 ShadingWhere shading is required to comply with 13.3.2 or 13.3.3, it must— be provided by an external permanent projection, such as a verandah, balcony,…