Table · ABCB Housing Provisions 2022
Table 13.3.2v Orientation sector conductance factor (OC): climate zone 5
| Wall construction | Floor type | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|---|
| Lightweight or masonry veneer | Floor in direct contact with the ground | 1.20 | 1.00 | 0.80 | 0.75 | 0.70 | 0.75 | 0.80 | 1.00 |
| Lightweight or masonry veneer | Suspended floor | 1.20 | 1.00 | 0.80 | 0.80 | 0.80 | 0.85 | 0.90 | 1.05 |
| Concrete or masonry | Floor in direct contact with the ground | 1.00 | 0.90 | 0.80 | 0.85 | 0.90 | 0.90 | 0.90 | 0.95 |
| Concrete or masonry | Suspended floor | 1.00 | 0.98 | 0.95 | 0.93 | 0.90 | 0.93 | 0.95 | 0.98 |
Table for 13.3.2 External glazing — winter
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2v.