WA 2.2.4 Determination of structural resistance of materials and forms of construction
Part 2.2 Structural provisions · varies 2.2.4 Determination of structural resistance of materials and forms of construction
Delete clause 2.2.4 and insert WA 2.2.4 as follows:
The following requirements, or any combination of them, must be used to determine the structural resistance of materials and forms of construction as appropriate:
Earthworks: H1D3(1).
Earth retaining structures: H1D3(2).
Termite risk management: H1D3(3).
Concrete construction (including slabs and footings, piled footings and reinforced and prestressed concrete structures): H1D4.
Piled footings: H1D12.
Post-installed and cast-in fastenings in concrete: AS 5216.
Masonry (including masonry veneer, unreinforced masonry and reinforced masonry): H1D5.
Steel construction (including steel framing and structural steel members): H1D6.
Timber construction (including design of timber structures, timber framing and design of nail-plated timber roof trusses): H1D6.
Composite steel and concrete: AS/NZS 2327.
Aluminium construction:
AS/NZS 1664.1.
AS/NZS 1664.2.
Roof construction (including plastic sheeting, roofing tiles, metal roofing and terracotta, fibre-cement and timber slates and shingles): H1D7.
Wall cladding: H1D7.
Glazed assemblies: H1D8.
Barriers and handrails (including stairway and ramp construction):
H5D3; and
AS/NZS 1170.1 for the determination of loading forces on a barrier.
Attachment of decks and balconies to external walls of buildings: H1D11.
Garage doors and other large access doors in openings not more than 3 m in height in external walls of buildings determined as being located in wind region B, C or D in accordance with Figure 2.2.3: AS/NZS 4505.
For high wind areas: requirements listed in (a) to (q) as appropriate or the Northern Territory Deemed to Comply Standards Manual.