Deemed-to-Satisfy Provision · NCC 2022 Volume One

C2D6 Two storey Class 2, 3 or 9c buildings

Part C2 Fire resistance and stability · NCC 2019: C1.5

Open C2D6 on NCC Online ↗

A building having a rise in storeys of 2 may be of Type C construction if—

it is a Class 2 or 3 building or a mixture of these classes and each sole-occupancy unit has—

access to at least 2 exits; or

its own direct access to a road or open space; or

it is a Class 9c building protected throughout with a sprinkler system (other than a FPAA101D or FPAA101H system) complying with Specification 17 and complies with the maximum compartment size specified in Table C3D3 for Type C construction.

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One C2D6.
Can't meet C2D6? A Performance Solution must meet the Performance Requirements it satisfies: C1P1, C1P2, C1P3, C1P4, C1P5, C1P6, C1P7, C1P8, C1P9. Start a Performance Solution →