Deemed-to-Satisfy Provision · NCC 2022 Volume One

C3D5 Requirements for open spaces and vehicular access

Part C3 Compartmentation and separation · NCC 2019: C2.4

Open C3D5 on NCC Online ↗

(1) An open space required by C3D4 must—

be wholly within the allotment except that any road, river, or public place adjoining the allotment, but not the farthest 6 m of it may be included; and

include vehicular access in accordance with (2); and

not be used for the storage or processing of materials; and

not be built upon, except for guard houses and service structures (such as electricity substations and pump houses) which may encroach upon the width of the space if they do not unduly impede fire-fighting at any part of the perimeter of the allotment or unduly add to the risk of spread of fire to any building on an adjoining allotment.

(2) Vehicular access required by this Part—

must be capable of providing continuous access for emergency vehicles to enable travel in a forward direction from a public road around the entire building; and

must have a minimum unobstructed width of 6 m with no part of its furthest boundary more than 18 m from the building and in no part of the 6 m width be built upon or used for any purpose other than vehicular or pedestrian movement; and

must provide reasonable pedestrian access from the vehicular access to the building; and

must have a load bearing capacity and unobstructed height to permit the operation and passage of fire brigade vehicles; and

must be wholly within the allotment except that a public road complying with (a), (b), (c) and (d) may serve as the vehicular access or part thereof.

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One C3D5.
Can't meet C3D5? A Performance Solution must meet the Performance Requirements it satisfies: C1P1, C1P2, C1P3, C1P4, C1P5, C1P6, C1P7, C1P8, C1P9. Start a Performance Solution →

Defined terms used