Performance Requirement · NCC 2022 Volume One

D1P2 Safe movement to and within a building

Part D1 Access and egress · NCC 2019: DP2

Open D1P2 on NCC Online ↗

So that people can move safely to and within a building, it must have—

walking surfaces with safe gradients; and

any doors installed to avoid the risk of occupants—

having their egress impeded; or

being trapped in the building; and

any stairways and ramps with—

slip-resistant walking surfaces on—

ramps; and

stairway treads or near the edge of the nosing; and

suitable handrails where necessary to assist and provide stability to people using the stairway or ramp; and

suitable landings to avoid undue fatigue; and

landings where a door opens from or onto the stairway or ramp so that the door does not create an obstruction; and

in the case of a stairway, suitable safe passage in relation to the nature, volume and frequency of likely usage.

Changed in NCC 2025. See NCC 2025 Volume One D1P2, or show what changed.

So that people can move safely to and within a … relation to the nature, volume and frequency of likely usage. Limitations D1P2(c) does not apply to threshold ramps, except D1P2(c)(i)(A) applies to threshold ramps provided for people with a disability.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used