F1P1 Managing rainwater impact on adjoining properties

Part F1 Surface water management, rising damp and external waterproofing · NCC 2019: FP1.1

Open F1P1 on NCC Online ↗

Surface water, resulting from a storm having an annual exceedance probability of 5% and which is collected or concentrated by a building or sitework, must be disposed of in a way that avoids the likelihood of damage or nuisance to any other property.

Changed in NCC 2025. See NCC 2025 Volume One F1P1, or show what changed.

Surface water, resulting from a storm having an annual exceedance probability (1) Water, including water on the surface of 5% and which the allotment that is collected or concentrated by a building or associated sitework, must be redirected to a drainage system to prevent — unhealthy or unsafe conditions, or loss of amenity for occupants within the building; and undue damage to internal surfaces and other building elements; and undue damage or nuisance to other buildings and any other property. (2) Water, required to be drained and resulting from a rain event with an annual exceedance probability, with a five-minute duration period, of 5% satisfies (1) if it is — disposed of in a way that avoids the likelihood of damage to the building; and conveyed through a drainage system to an appropriate outfall. (3) Water resulting from a rain event with an annual exceedance probability, with a five-minute duration period, of 1% collected or nuisance concentrated by building elements satisfies (1) if it is disposed of in a way that prevents — unhealthy or unsafe conditions, or loss of amenity for occupants within the building; and undue damage to any internal surfaces and other property. building elements. (4) Water resulting from a rain event in (2) and (3), subject to wind action with an annual exceedance probability of 4%, collected or concentrated by a building satisfies (1) if it is disposed of in a way that prevents — unhealthy or unsafe conditions, or loss of amenity for occupants within the building; and undue damage to internal surfaces and other building elements. Notes For the purposes of F1P1(3)— building elements include external walls, openings around windows and external doors, roofs, balconies, podiums, attached awnings, similar horizontal surface parts of a building and stormwater overflow systems; and an annual exceedance probability of 5% can be applied to awnings and roofs with or without eaves gutters and where overflow, if applicable, is external to the building. Exemptions F1P1(1), F1P1(3) and F1P1(4) do not apply to — condensation; or a private garage, tool shed, sanitary compartment or the like separate from, or forming part of, a building used for other purposes; or an open spectator stand or open-deck carpark.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Defined terms used