NCC 2022 Volume One
Part F1 Surface water management, rising damp and external waterproofing
15 clauses · Open on NCC Online ↗
- F1O1 ObjectiveThe Objective of this Part is to— safeguard occupants from illness or injury and protect the building from damage caused by— surface water; and…
- F1F1 Protection from redirected surface waterA building, including any associated sitework, is to be constructed in a way that protects people and other property from the adverse effects of…
- F1F2 Resistance to rain, surface water and ground waterA building is to be constructed to provide resistance to moisture penetrating from the outside, including rising from the ground.
- F1P1 Managing rainwater impact on adjoining propertiesSurface water, resulting from a storm having an annual exceedance probability of 5% and which is collected or concentrated by a building or…
- F1P2 Preventing rainwater from entering buildingsSurface water, resulting from a storm having an annual exceedance probability of 1%, must not enter the building. Limitations F1P2 does not apply…
- F1P3 Rainwater drainage systemsA drainage system for the disposal of surface water resulting from a storm having an annual exceedance probability of— 5% must— convey surface water…
- F1P4 Rising damp SAMoisture from the ground must be prevented from causing— undue dampness or deterioration of building elements; and unhealthy or dangerous…
- F1D1 Deemed-to-Satisfy Provisions SAWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements F1P1 to F1P4 are satisfied by complying with F1D2 to F1D8. (2) Where a…
- F1D2 Application of PartF1D4 and F1D5 do not apply to a roof with a covering complying with F3D2(a) to (d). (2) F1D3 to F1D5 do not apply to a balcony, podium or similar…
- F1D3 Stormwater drainageStormwater drainage must be designed and constructed in accordance with AS/NZS 3500.3.
- F1D4 Exposed jointsExposed joints in the drainage surface on a roof, balcony, podium or similar horizontal surface part of a building must— be protected in accordance…
- F1D5 External waterproofing membranesA roof, balcony, podium or similar horizontal surface part of a building must be provided with a waterproofing membrane— consisting of materials…
- F1D6 Damp-proofing SAExcept for a building covered by (3), moisture from the ground must be prevented from reaching— the lowest floor timbers and the walls above the…
- F1D7 Damp-proofing of floors on the ground SAIf a floor of a room is laid on the ground or on fill, moisture from the ground must be prevented from reaching the upper surface of the floor and…
- Table F1D8 Subfloor openings and ground clearanceClimatic zone (see Figure F1D8) | Minimum aggregate subfloor ventilation openings without a membrane (mm2/m of wall) | Minimum aggregate subfloor…