New South Wales variation · NCC 2022 Volume One

NSW G5P1 Bushfire resistance

Part G5 Construction in bushfire prone areas · varies G5P1 Bushfire resistance

Open on NCC Online ↗

Delete clause G5P1 and insert NSW G5P1 as follows:

A building that is constructed in a designated bushfire prone area must be designed and constructed to—

reduce the risk of ignition from a design bushfire with an annual exceedance probability not more than 1:100 years, or 1:200 years for a Class 9 building; and

take account of the assessed duration and intensity of the fire actions of the design bushfire; and

prevent internal ignition of the building and its contents; and

maintain the structural integrity of the building for the duration of the design bushfire.

Applications

NSW G5P1 only applies in a designated bushfire prone area to—

a Class 2 or 3 building; or

a Class 4 part of a building; or

a Class 9 building that is a special fire protection purpose; or

a Class 10a building or deck immediately adjacent or connected to a building or part of a type listed in (a), (b) or (c).

Changed in NCC 2025. See NCC 2025 Volume One NSW G5P1, or show what changed.

Delete clause G5P1 and insert NSW G5P1 as follows: A Except as amended by Planning for Bush Fire Protection, a building that is constructed in a designated bushfire prone area … part of a type listed in (a), (b) or (c).

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause

Other states and territories