NCC 2022 Volume One
New South Wales variations
170 NSW variations to NCC 2022 Volume One: clauses replaced, added or deleted in New South Wales. Search with NSW variations.
- NSW Material or assembly location Flammability Index Spread-of-Flame Index Smoke-Developed Index Fire control rooms subject to Specification 19 and…
- NSW A6G7 Class 6 buildingsDelete clause A6G7 and insert NSW A6G7 as follows: A Class 6 building is a shop or other building for sale of goods by retail or the supply of…
- NSW C2D11 Fire hazard propertiesDelete clause C2D11 and insert NSW C2D11 as follows: (1) The fire hazard properties of the following internal linings, materials and assemblies…
- NSW C3D6 Class 9 buildingsDelete subclause C3D6(3) and insert NSW C3D6(3) as follows: (3) A Class 9c building must comply with the following: A building must be divided into…
- NSW C4D12 Bounding construction: Class 2 and 3 buildings and Class 4 partsDelete subclause C4D12(4) and insert NSW C4D12(4) as follows: (4) Except as provided for in NSW C4D12(5), protection for a doorway required under…
- NSW D2D3 Number of exits requiredDelete subclause D2D3(4) and insert NSW D2D3(4) as follows: (4) Class 9 buildings— In addition to any horizontal exit, not less than 2 exits must be…
- NSW D2D8 Width of exits and paths of travel to exitsInsert NSW subclause D2D8(5) in clause D2D8 as follows: (5) In a Class 9b building used as an entertainment venue— the aggregate width must be not…
- NSW D2D9 Width of doorways in exits or paths of travel to exitsDelete clause D2D9 and insert NSW D2D9 as follows: In a required exit or path of travel to an exit, the unobstructed width of a doorway must be not…
- NSW D2D15 Discharge from exitsDelete subclause D2D15(6) and insert NSW D2D15(6) as follows: (6) In a Class 9b building used as an entertainment venue, at least half of the…
- NSW D3D2 Application of PartDelete clause D3D2 and insert NSW D3D2 as follows: (1) Except for— D3D14, D3D15(a), D3D17, D3D18, D3D19, D3D20, D3D22(5), D3D22(6), D3D26 and D3D29,…
- NSW D3D14 Goings and risersDelete subclause D3D14(1) and insert NSW D3D14(1) as follows: (1) A stairway must have— not more than 18 and not less than 2 risers in each flight;…
- NSW D3D16 ThresholdsDelete clause D3D16 and insert NSW D3D16 as follows: The threshold of a doorway must not incorporate a step or ramp at any point closer to the…
- NSW D3D18 Height of barriersDelete subclause D3D18(1) and insert NSW D3D18(1) as follows: (1) The height of a barrier required by D3D17 must be not less than the following: For…
- NSW D3D24 Doorways and doorsDelete subclause D3D24(2) and insert NSW D3D24(2) as follows: (2) A doorway serving as a required exit or forming part of a required exit, or a…
- NSW D3D26 Operation of latchDelete subclause D3D26(5) and insert NSW D3D26(5) as follows: (5) The requirements of (1) and (2) do not apply in a Class 9b building (other than a…
- NSW D3D31 Doors in paths of travel to an entertainment venueInsert NSW clause D3D31 in clause D3D31 as follows: In a Class 9b building used as an entertainment venue, a doorway in a path of travel must comply…
- NSW E2D10 Buildings not more than 25 m in effective height: large isolated buildings subject to C3D4Delete clause E2D10 and insert NSW E2D10 as follows: (1) In a Class 5, 6, 7, 8 or 9 building of not more than 25 m in effective height, and which…
- NSW E2D16 Class 9b – assembly buildings: allDelete clause E2D16 and insert NSW E2D16 as follows: The following provisions apply to all Class 9b assembly buildings: A building or part of a…
- NSW E2D17 Class 9b – assembly buildings: night clubs, discotheques and the likeDelete clause E2D17 and insert NSW E2D17 as follows: A building or part of a building being a night club, discotheque or the like, must be provided…
- NSW E2D18 Class 9b – assembly buildings: exhibition halls, museums and art galleriesDelete clause E2D18 and insert NSW E2D18 as follows: A building or part of a building used as an exhibition hall, museum, art gallery or the like,…
- NSW E2D19 Class 9b – assembly buildings: other assembly buildings (not listed in NSW E2D16 to E2D18)Delete clause E2D19 and insert NSW E2D19 as follows: (1) Unless otherwise described in (2), in a building or part of a building used as an assembly…
- NSW E2D20 Class 9b assembly buildings: other assembly buildings (not listed in E2D16 to E2D19)This clause been deliberately left blank E2D20 does not apply in NSW. This clause is deleted from the BCA in NSW, as requirements for Class 9b –…
- NSW E4D6 Direction signsDelete clause E4D6 and insert NSW E4D6 as follows: If an exit is not readily apparent to persons occupying or visiting the building, then exit signs…
- NSW F4D10 Microbial (legionella) controlThis clause been deliberately left blank F4D10 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and…
- NSW F4P6 Microbial control for water systemsThis clause been deliberately left blank F4P6 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and…
- NSW F6D6 Ventilation of roomsDelete clause F6D6 and insert NSW F6D6 as follows: A habitable room, office, shop, factory, workroom, sanitary compartment, bathroom, shower room,…
- NSW G1D2 Swimming poolsDelete clause G1D2 and insert NSW G1D2 as follows: (1) NSW G1D2(2) applies to the technical construction requirements for barriers to restrict…
- NSW G1D5 Provision for cleaning windowsInsert NSW clause G1D5 in clause G1D5 as follows: (1) A building must provide for a safe manner of cleaning any windows located 3 or more storeys…
- NSW G1P2 Swimming pool access and water recirculation systemsDelete clause G1P2 and insert NSW G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be continuous for the full extent of…
- NSW G5D2 Application of PartDelete clause G5D2 and insert NSW G5D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply in a designated bushfire prone area to— a…
- NSW G5D3 ProtectionDelete clause G5D3 and insert NSW G5D3 as follows: In a designated bushfire prone area, a Class 2 building, a Class 3 building, a Class 4 part of a…
- NSW G5D4 Protection – Class 9 buildings used as a special fire protection purposeDelete clause G5D4 and insert NSW G5D4 as follows: In a designated bushfire prone area, a Class 9 building that is a special fire protection purpose…
- NSW G5P1 Bushfire resistanceDelete clause G5P1 and insert NSW G5P1 as follows: A building that is constructed in a designated bushfire prone area must be designed and…
- NSW G5P2 Additional bushfire requirements for Class 9 buildings that are a special fire protection purposeDelete clause G5P2 and insert NSW G5P2 as follows: A building that is constructed in a designated bushfire prone area and occupied by people who may…
- NSW I1D1 Application of PartDelete clause I1D1 and insert NSW I1D1 as follows: (1) For a Class 9b building or part of a building that is not an entertainment venue— the…
- NSW I4D1 Application of PartThis Part applies to every entertainment venue as described in the Environmental Planning and Assessment Regulation 2021.
- NSW I4D2 Fire separationIf an entertainment venue forms part only of a building, then— the whole of the entertainment venue; or the part containing the stage, backstage…
- NSW I4D3 Foyer spaceWhere an entertainment venue is used principally for the purpose of— exhibiting films; or conducting live stage productions, foyer space (excluding…
- NSW I4D4 Sprinkler systems for common foyersIn an entertainment venue, where multiple auditoriums have a foyer in common, the following applies: If the foyer serves not more than 2…
- NSW I4D5 Conventional stages: applicationNSW I4D6 to NSW I4D9 apply to a conventional stage, that is, a stage which is separated from the auditorium by a proscenium wall incorporating a…
- NSW I4D6 Conventional stages: extent of stage areaIf a room or area is not separated from the remainder of a conventional stage by construction having an FRL of not less than 60/60/60, the room or…
- NSW I4D7 Conventional stages: small stagesA stage which is more than 50 m2 but not more than 150 m2 in area must have 2 or more means of egress from the stage and backstage area provided…
- NSW I4D8 Conventional stages: large stagesA stage which is more than 150 m2 in area— must have installed directly above the stage a suitable sprinkler system (other than a FPAA101D or…
- NSW I4D9 Conventional stages: fire separation of stagesA stage which is more than 50 m2 in area, and all areas below such a stage, must (with the exception of the proscenium opening) be separated from…
- NSW I4D10 Non-conventional stages: applicationNSW I4D11 and NSW I4D12 apply to a stage that is not a conventional stage within the meaning of NSW I4D5.
- NSW I4D11 Non-conventional stages: small stagesA stage which is more than 50 m2 but not more than 150 m2 in area must have at least 2 means of egress from the backstage area.
- NSW I4D12 Non-conventional stages: large stagesA stage which is more than 150 m2 in area must have at least 2 means of egress from the backstage area.
- NSW I4D13 Flying sceneryWhere there is a grid or other means of flying scenery over a conventional stage or non-conventional stage— the stage must be provided with a…
- NSW I4D14 Load noticeA notice indicating the actual distributed and concentrated load for which the stage floor has been designed must be conspicuously and permanently…
- NSW I4D15 Safety curtainsA safety curtain required by NSW I4D8 must— be made of non-combustible material; and be so fitted that, when it is closed, it forms an efficient…
- NSW I4D16 Safety curtains — additional requirementsA rigid safety curtain required by NSW I4D13 must comply with the requirements of NSW I4D15 and it must— be vertically hung from steel cables; and…
- NSW I4D17 Seating in rows: applicationNSW I4D18 to NSW I4D25 do not apply to continental seating or seating at tables.
- NSW I4D18 Seating in rows: number of seatsSubject to NSW I4D22, where seating is arranged in rows, the maximum number of seats in each row must not exceed— 8 where there is an aisle at one…
- NSW I4D19 Seating in rows: chairs used for seatingChairs used for seating must— where they have arms, be at least 500 mm from centre to centre; and where they do not have arms, be at least 450 mm…
- NSW I4D20 Seating in rows: chairs in auditoriums — level floorsChairs in an auditorium that has a level floor must be— securely fastened to the floor; or secured together in groups of not less than 4 and not…
- NSW I4D21 Seating in rows: chairs in auditoriums — sloping floorsChairs in an auditorium having a sloping floor, or having stepped or inclined platforms, must be securely fastened to the floor or platform.
- NSW I4D22 Seating in rows: radiating aisles in seating areasWhere seating is securely fastened to the floor and arranged in rows of concentric circles, semi-circles or segments of circles, with radiating…
- NSW I4D23 Seating in rows: aisles and cross-oversWhere aisles and cross-overs are provided— each aisle must have a width of at least 1000 mm and each cross-over must have a width of at least 1500…
- NSW I4D24 Seating in rows: platforms and stepsWhere an aisle contains platforms or steps— the platforms and steps must extend for the full width of the aisle; and if there are no intervening…
- NSW I4D25 Seating in rows: stepped platformsWhere stepped platforms without chairs or stepped platforms with bench seats, are used for seating— each platform must be at least 700 mm deep; and…
- NSW I4D26 Continental seating: applicationNSW I4D27 to NSW I4D35 apply to continental seating.
- NSW I4D27 Continental seating: seating to be fastenedSeating must be securely fastened to the floor.
- NSW I4D28 Continental seating: maximum seats per rowThe number of seats in a row must not exceed 120.
- NSW I4D29 Continental seating: depth of seatingThe depth of each row of seating (that is, the distance between the back of the row in front or, if there is a guardrail in front, between the back…
- NSW I4D30 Continental seating: clearance between rowsThe minimum lateral clearance between each row of seating must, in respect of a row containing a number of seats specified in Column 1 of NSW Table…
- NSW I4D31 Continental seating: chairs used for seatingChairs used for seating must comply with NSW I4D19(a) and (b).
- NSW I4D32 Continental seating: egress doorwaysEgress doorways through the walls of the auditorium— must have an aggregate width of at least twice the sum of the clearances specified in Column 3…
- NSW I4D33 Continental seating: clear areasA clear area— must be provided from each end of each row to an egress doorway in the wall of the auditorium; and must have a width of at least the…
- NSW I4D34 Continental seating: minimum clear spaceAt the entrance from a row to a clear area, there must be a clear level floor space having a width of at least the clearance specified for the row…
- NSW I4D35 Continental seating: doorsA door fitted to the egress doorway in the wall of an auditorium must comply with NSW D3D16 and NSW D3D24(2).
- NSW I4D36 Provision of guardrails: locationGuardrails must be provided— along the fascia of each balcony or box; and if there is a stepped floor, along the front edge of each cross-over; and…
- NSW I4D37 Provision of guardrails: fixed back seatsIf seats with fixed backs are provided, guardrails that extend for the full width of the seating, must be provided at least 500 mm above the…
- NSW I4D38 Provision of guardrails: steps between platformsIf— there is more than one intervening step in an aisle between levels of platforms, a guardrail must be provided (at a vertical height of at least…
- NSW I4D39 Guardrails for seating areas: applicationNSW I4D40 to NSW I4D42 apply to seating areas.
- NSW I4D40 Guardrails for seating areas: continental seatingWhere a guardrail is provided in front of a row of chairs— the distance between the back of each chair in that row, and the guardrail must be not…
- NSW I4D41 Guardrails for seating areas: balconies and boxesA guardrail provided along the fascia of a balcony or box— if it is located at the foot of a stepped aisle, must have its top surface at least 900…
- NSW I4D42 Guardrails for seating areas: cross-oversA guardrail provided along the front edge of a cross-over on a stepped floor— must be at least 750 mm high; and must extend the full distance…
- NSW I4D43 Dressing roomsA dressing room or two or more adjoining dressing rooms, having a total floor area of more than 50 m2, must— be separated from other parts of the…
- NSW I4D44 StoreroomsA storeroom must be separated from other parts of the building by construction having an FRL of not less than 60/60/60.
- NSW I4D45 Projection suites: ApplicationNSW I4D45 to NSW I4D48 apply to projection suites. (2) A projection suite must be provided in an entertainment venue intended to be used for the…
- NSW I4D46 Projection suites: rooms to be providedA projection suite in accordance with the staffing requirements of Schedule 72 of the Environmental Planning and Assessment Regulation 2021 must…
- NSW I4D47 Projection suites: fire separationA projection suite must be separated from all other internal parts of the building in which it is located by construction having an FRL of not less…
- NSW I4D48 Projection suites: concession for protection of some openingsIf a projection or observation port is not more than 0.1 m2 in area— a metal shutter not less than 1.5 mm thick may be fitted thereto instead of the…
- NSW I4D49 Basement storeysWhere an entertainment venue includes not more than 2 basement storeys— all required exits from the basement must be enclosed in non-combustible…
- NSW I4D50 Basement storeys: more than twoIf the entertainment venue includes more than 2 basement storeys— the construction must be of at least Type B; and all required exits from the…
- NSW I4D51 Electric mains installation: main switchboardThe switchboard containing the main isolation switch must— be located in a position that is readily accessible to authorised persons, and to the…
- NSW I4D52 Electric mains installation: circuit protectionProtection of the final sub-circuit originating at a switchboard or distribution board must be by means of circuit breakers.
- NSW I4D53 Electric mains installation: separate sub-mainsWhere an entertainment venue has its mains supply in common with that of another building or where it is a part of a building— the entertainment…
- NSW I4D54 Lighting: lighting switchesAny switch controlling the lighting system must not be accessible. (2) Where, during normal use, general lighting may be dimmed or switched off, an…
- NSW I4D55 Lighting: lighting levelsWhere the lamps utilised in the general lighting are of a type that will not relight immediately after the restoration of the primary electricity…
- NSW I4D56 Lighting: provision of aisle lightingWhere general lighting is to be either dimmed or extinguished when the public is in attendance and where the floor is stepped or at an inclination…
- NSW I4D57 Lighting: aisle lighting power supplyWhere an aisle light is installed in a seat frame, it must be supplied at a voltage of not more than 32 volts AC or 115 volts DC.
- NSW I4D58 Lighting: aisle lighting alternative lighting supplyAisle lighting must be provided with an alternative electricity supply that— is capable of being automatically energised in the event of failure of…
- NSW I4D59 Automatic smoke-and-heat vents for stagesAn automatic smoke-and-heat vent system required by NSW E2D16(c) for stages and backstages must— be capable of automatic operation by the inclusion…
- NSW I4D60 Solid fuel burning stoves and open fire placesSolid fuel burning stoves and open fire places must not be installed in premises designed for the purpose of— exhibiting films; or conducting live…
- NSW I4D61 Fuel gas cylinders: generalFuel gas cylinders must— be housed in an enclosure that is located outside the building; and comply with the ventilation requirements of AS/NZS 1596.
- NSW I4D62 Fuel gas cylinders: enclosuresAn enclosure referred to in NSW I4D61— must be located not less than 3 m from any window, door, vent or other opening; and if located 3 m or more…
- NSW I5D1 Application of PartThis Part applies to temporary structures used as entertainment venues.
- NSW I5D2 Exits — exclusionsIn this Part, a reference to an entrance or exit does not include a reference to an entrance or exit provided for persons or animals performing in a…
- NSW I5D3 Location of exitsExits must be so provided and arranged as to afford a ready means of egress from all parts of a temporary structure.
- NSW I5D4 Exits to be providedWithout limiting the generality of NSW I5D3— the number of exits to be provided for a temporary structure designed to accommodate a number of…
- NSW I5D5 Vertical clearance for exitsEvery part of an entrance or exit must provide a minimum unobstructed height of 2000 mm and, where the entrance or exit is beneath a stepped seating…
- NSW I5D6 Curtains across exitsA flap or curtain used to cover an exit must be so designed that, when it is secured, it will not obstruct or impede egress.
- NSW I5D7 Curtains and blindsCurtains and blinds for use in a temporary structure must comply with NSW Table S7C7.
- NSW I5D8 FabricsFabric that is used in the construction of a temporary structure must have— a Flammability Index of not more than 6 where used— within a height of 4…
- NSW I5D9 GuardrailsA rigid guardrail must be provided at each end of a stepped or inclined platform, at least 750 mm high above the floor of the platform, and must…
- NSW I5D10 SeatingSeating must be provided in accordance with NSW I4D18, NSW I4D19, NSW I4D20(b), NSW I4D22(a) and (c), NSW I4D23(a) and NSW I4D25(a), (b), (c) and (d).
- NSW I5D11 Sanitary accommodationSuitable sanitary accommodation must be provided at a location convenient to the temporary structure.
- NSW I5D12 Projection suitesAny projection suite must comply with NSW I4D47 and NSW I4D48.
- NSW I5D13 Fireplaces and heatingNo fireplace or other form of heating equipment may be installed in a temporary structure, without the consent of the approval authority.
- NSW I5D14 Electrical servicesElectrical services connected to the local supply authority’s mains, to a generating plant or to a battery supply must comply with— the requirements…
- NSW I5D15 Artificial lighting: generalArtificial lighting must be provided, and must comply with NSW I4D54 and NSW I4D55.
- NSW I5D16 Emergency lightingEmergency lighting must be provided to the areas provided with artificial lighting under NSW I5D15 and must include a sufficient number of lamps to…
- NSW I5D17 Emergency lighting power supplyWhere emergency lighting is provided, the capacity of the battery and charging system must be sufficient to provide the illumination required by NSW…
- NSW I5D18 Exit signsExit signs must be provided above all exits and in such other locations as may be required by NSW E4D6 and must comply with E4D5 and E4D8.
- NSW I5D19 Fire-fighting servicesFire-fighting services and appliances must be so provided as to afford adequate protection and must be so located as the approving authority, on the…
- NSW I6D1 Application of PartThis Part applies to drive-in theatres.
- NSW I6D2 Speaker standardsSpeaker standards must— be placed at a minimum of 5.5 m centres in a line along each parking ramp; and be capable of being illuminated throughout…
- NSW I6D3 Lines of speaker standardsLines of speaker standards along parking ramps must be placed at a distance of not less than 12.2 m apart.
- NSW I6D4 Electrical servicesThe following electrical services must be installed underground— the supply authority’s conductors within the site and the consumer’s mains, unless…
- NSW I6D5 Vehicular entrancesEach public vehicular entrance to or exit from the drive-in theatre must be capable of being fully illuminated by flood lights that are so placed…
- NSW I6D6 LightingDriveways — Entrance and exit driveways, and the perimeter of the holding area, must be capable of being continuously illuminated by lamps capable…
- NSW J1F1 Energy efficiencyA building must— reduce the energy consumption and energy peak demand of key energy using equipment; and reduce the greenhouse gas emissions that…
- NSW J1O1 ObjectiveThe Objective of this Section is to— reduce energy consumption and energy peak demand; and reduce greenhouse gas emissions; and improve occupant…
- NSW J1P1 Energy useA building including its services, must have features that facilitate the efficient use of energy appropriate to— the function and use of the…
- NSW J1P4 Renewable energy and electric vehicle chargingA building must have features that facilitate the future installation of on-site renewable energy generation and storage and electric vehicle…
- NSW J1P5 Building fabric—Class 2 building and Class 4 parts of a buildingThermal insulation in a building must be installed in a manner and have characteristics, which facilitate the efficient use of energy for artificial…
- NSW J1P6 Building sealing—Class 2 building and Class 4 parts of a buildingA building must have, to the degree necessary, a level of building sealing against air leakage to facilitate the efficient use of energy for…
- NSW J1P7 Services—Class 2 building and Class 4 parts of a buildingA building’s services must have features that, to the degree necessary, facilitate the efficient use of energy appropriate to— the function and use…
- NSW J1V1 NABERS EnergyFor a Class 5 building, compliance with NSW J1P1 is verified when— a minimum 5.5-star NABERS Energy base building Commitment Agreement is obtained;…
- NSW J1V2 Green starFor a Class 3, 5, 6, 7, 8 or 9 building, compliance with NSW J1P1 is verified when— the building complies with the simulation requirements, and is…
- NSW J1V3 Verification using a reference buildingFor a Class 3, 5, 6, 7, 8 or 9 building, compliance with NSW J1P1 is verified when— it is determined that the annual greenhouse gas emissions of the…
- NSW J1V4 Verification of building envelope sealingCompliance with NSW J1P1(e) and NSW J1P6 is verified for building envelope sealing when the envelope is sealed at an air permeability rate, tested…
- NSW J2D1 Deemed-to-Satisfy ProvisionsDelete subclause J2D1(1) and insert NSW J2D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 to…
- NSW J2D2 Application of Section JDelete clause J2D2 and insert NSW J2D2 as follows: (1) For a Class 3 and 5 to 9 building, Performance Requirement NSW J1P1 is satisfied by complying…
- NSW J3D1 Deemed-to-Satisfy ProvisionsDelete subclause J3D1(1) and insert NSW J3D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 to…
- NSW J3D2 Application of PartDelete clause J3D2 and insert NSW J3D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply to building elements forming the external…
- NSW J3D3 Reducing heating and cooling loads of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building using house energy rating softwareThis clause been deliberately left blank J3D3 does not apply in NSW.
- NSW J3D4 Ceiling fans in a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis clause been deliberately left blank J3D4 does not apply in NSW.
- NSW J3D7 Roofs and ceilings of a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis clause been deliberately left blank J3D7 does not apply in NSW.
- NSW J3D8 External walls of a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis clause been deliberately left blank J3D8 does not apply in NSW.
- NSW J3D9 Wall-glazing construction of a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis clause been deliberately left blank J3D9 does not apply in NSW.
- NSW J3D10 Floors of a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingDelete subclause J3D10(1) and insert NSW J3D10(1) as follows: (1) This subclause does not apply in NSW. Delete subclause J3D10(2) and insert NSW…
- NSW J3D11 External winter glazing of a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis clause been deliberately left blank J3D11 does not apply in NSW.
- NSW J3D12 External summer glazing of a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis clause been deliberately left blank J3D12 does not apply in NSW.
- NSW J3D13 Shading of a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis clause been deliberately left blank J3D13 does not apply in NSW.
- NSW J3D14 Net equivalent energy usage of a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis clause been deliberately left blank J3D14 does not apply in NSW.
- NSW J3D15 Net equivalent energy usage for a sole-occupancy unit of a Class 2 building or Class 4 part of building – home energy rating softwareThis clause been deliberately left blank
- NSW J4D1 Deemed-to-Satisfy ProvisionsDelete subclause J4D1(1) and insert NSW J4D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 to…
- NSW J4D2 Application of PartDelete clause J4D2 and insert NSW J4D2 as follows: (1) The Deemed-to-Satisfy Provisions of this Part apply to building elements forming the envelope…
- NSW J4D3 Thermal construction—generalDelete clause J4D3 and insert NSW J4D3 as follows: (1) Where required, insulation must comply with AS/NZS 4859.1 and be installed so that it— abuts…
- NSW J4D6 Walls and glazingDelete clause J4D6 and insert NSW J4D6 as follows: (1) The Total System U-Value of wall-glazing construction, including wall-glazing construction…
- NSW J5D1 Deemed-to-Satisfy ProvisionsDelete subclause J5D1(1) and insert NSW J5D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 to…
- NSW J5D2 Application of PartDelete clause J5D2 and insert NSW J5D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply to elements forming the envelope of a Class 2…
- NSW J5D5 Windows and doorsDelete clause J5D5 and insert NSW J5D5 as follows: (1) A door, openable window or the like must be sealed— when forming part of the envelope; or in…
- NSW J6D1 Deemed-to-Satisfy ProvisionsDelete subclause J6D1(1) and insert NSW J6D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 to…
- NSW J6D2 Application of PartDelete clause J6D2 and insert NSW J6D2 as follows: (1) The Deemed-to-Satisfy Provisions of this Part do not apply to a Class 8 electricity network…
- NSW J6D10 Space heatingDelete subclause J6D10(2) and insert NSW J6D10(2) as follows: (2) An electric heater may be used for heating a bathroom in a Class 3, 9a or 9c…
- NSW J7D1 Deemed-to-Satisfy ProvisionsDelete subclause J7D1(1) and insert NSW J7D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 to…
- NSW J7D2 Application of PartDelete clause J7D2 and insert NSW J7D2 as follows: (1) The Deemed-to-Satisfy Provisions of this Part do not apply to a Class 2 building or a Class 4…
- NSW J7D3 Artificial lightingDelete subclause J7D3(1) and insert NSW J7D3(1) as follows: (1) This subclause does not apply in NSW. Delete subclause J7D3(2) and insert NSW…
- NSW J7D4 Interior artificial lighting and power controlDelete subclause J7D4(4) and insert NSW J7D4(4) as follows: (4) 95% of the light fittings in a building or storey of a building, other than a Class…
- NSW J8D1 Deemed-to-Satisfy ProvisionsDelete subclause J8D1(1) and insert NSW J8D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 to…
- NSW J8D3 Swimming pool heating and pumpingDelete clause J8D3 and insert NSW J8D3 as follows: (1) Heating for a swimming pool must be by— a solar heater; or a heater using reclaimed heat from…
- NSW J8D4 Spa pool heating and pumpingDelete clause J8D4 and insert NSW J8D4 as follows: (1) Heating for a spa pool that shares a water recirculation system with a swimming pool must be…
- NSW J9D1 Deemed-to-Satisfy ProvisionsDelete subclause J9D1(1) and insert NSW J9D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements NSW J1P1 to…
- NSW Part G7 Livable housing designThis Part has deliberately been left blank. Part G7 does not apply in NSW as livable housing design requirements do not apply to sole-occupancy…
- NSW S20C8 System monitoringDelete clause S20C8 and insert NSW S20C8 as follows: The following installations must be connected to a fire alarm monitoring system connected to a…
- NSW S43C2 Separation from classified vegetationThis clause been deliberately left blank S43C2 does not apply in NSW as Asset Protection Zones must be determined in accordance with Planning for…
- NSW S43C11 Supply of water for fire-fighting purposesDelete clause S43C11 and insert NSW S43C11 as follows: Water for fire-fighting purposes must be available and consist of— A fire hydrant system…