New South Wales variation · NCC 2022 Volume One
NSW I4D2 Fire separation
NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres
If an entertainment venue forms part only of a building, then—
the whole of the entertainment venue; or
the part containing the stage, backstage area and auditorium,
must be separated from the other parts of the building by construction having an FRL of not less than 60/60/60.
Changed in NCC 2025. See NCC 2025 Volume One NSW I4D2, or show what changed.
Delete clause I4D2 and insert NSW I4D2 as follows: If an entertainment venue forms part only of a building, … by construction having an FRL of not less than 60/60/60.
Removed words are struck through; added words are highlighted. Comparison of the text only.
Other states and territories
- VIC The Deemed-to-Satisfy Provisions of this Part apply to Class 3 and Class 9a residential aged care buildings and Class…
- WA The Deemed-to-Satisfy Provisions of this Part apply to a WA public building or part of a building.
- TAS Performance RequirementsTAS I4P1 to TAS I4P13 are satisfied by complying with the relevant provisions of TAS I4D3 to…