A guardrail provided along the fascia of a balcony or box—

if it is located at the foot of a stepped aisle, must have its top surface at least 900 mm above the floor of the balcony or box; and

if it is not located at the foot of a stepped aisle, must have its top surface at least 750 mm above the floor; and

if it has a ledge more than 70 mm wide, must have the top surface of the ledge sloping downwards towards the floor of the balcony or box at an angle of at least 30 degrees from the horizontal; and

must have an unperforated kerb or toe guard extending for at least 300 mm above the floor.

Changed in NCC 2025. See NCC 2025 Volume One NSW I4D41, or show what changed.

Delete clause I4D41 and insert NSW I4D41 as follows: A guardrail provided along the fascia of a balcony or … guard extending for at least 300 mm above the floor.