New South Wales variation · NCC 2022 Volume One
NSW I4D43 Dressing rooms
NSW Part I4 Entertainment venues other than temporary structures and drive-in theatres
A dressing room or two or more adjoining dressing rooms, having a total floor area of more than 50 m2, must—
be separated from other parts of the building by construction having an FRL of not less than 60/60/60; and
have at least 2 means of egress as remote from each other as possible, one of which must discharge—
directly to a road or open space; or
through a fire-isolated exit to a road or open space.
Changed in NCC 2025. See NCC 2025 Volume One NSW I4D43, or show what changed.
Delete clause I4D43 and insert NSW I4D43 as follows: A dressing room or two or more adjoining dressing rooms, … through a fire-isolated exit to a road or open space.
Removed words are struck through; added words are highlighted. Comparison of the text only.