NSW I5D9 Guardrails
NSW Part I5 Temporary structures
(1) A rigid guardrail must be provided at each end of a stepped or inclined platform, at least 750 mm high above the floor of the platform, and must extend—
in the case of a stepped platform, from the front of the first riser; and
in the case of an inclined platform, from the front of the first row of seating,
to the back of the highest platform and along the rear of that platform for its full width.
(2) A rigid guardrail must not obstruct any aisle, cross-over or exit.
Changed in NCC 2025. See NCC 2025 Volume One NSW I5D9, or show what changed.
Delete clause I5D9 and insert NSW I5D9 as follows: (1) A rigid guardrail must be provided at each end … rigid guardrail must not obstruct any aisle, cross-over or exit.