New South Wales variation · NCC 2022 Volume One

NSW J1P6 Building sealing—Class 2 building and Class 4 parts of a building

NSW Part J1 Energy efficiency performance requirements

Open on NCC Online ↗

A building must have, to the degree necessary, a level of building sealing against air leakage to facilitate the efficient use of energy for artificial heating and cooling appropriate to—

the function and use of the building; and

the internal environment; and

the geographic location of the building.

Applications

NSW J1P6 only applies to a Class 2 building or Class 4 part of a building, except—

a building in climate zones 2 and 5 where the only means of air-conditioning is by using an evaporative cooler; and

a permanent building opening in a space where a gas appliance is located, that is necessary for the safe operation of a gas appliance; and

parts that cannot be fully enclosed.

Not in NCC 2025. No NSW J1P6 in NCC 2025 Volume One.