New South Wales variation · NCC 2022 Volume One

NSW J8D4 Spa pool heating and pumping

Part J8 Heated water supply and swimming pool and spa pool plant · varies J8D4 Spa pool heating and pumping

Open on NCC Online ↗

Delete clause J8D4 and insert NSW J8D4 as follows:

(1) Heating for a spa pool that shares a water recirculation system with a swimming pool must be by—

a solar heater; or

a heater using reclaimed heat from another process such as reject heat from a refrigeration plant; or

a geothermal heater; or

a gas heater that—

if rated to consume 500 MJ/hour or less, achieves a minimum gross thermal efficiency of 86%; or

if rated to consume more than 500 MJ/hour, achieves a minimum gross thermal efficiency of 90%; or

a heat pump; or

a combination of (a) to (e).

(2) Where some or all of the heating required by (1) is by a gas heater or a heat pump, the spa pool must have—

a cover with a minimum R-Value of 0.05; and

a push button and a time switch to control the operation of the heater.

(3) A time switch must be provided to control the operation of a circulation pump for a spa pool having a capacity of 680 L or more.

(4) Where required, a time switch must be capable of switching electric power on and off at variable pre-programmed times and on variable pre-programmed days.

(5) Pipework carrying heated or chilled water for a spa pool must comply with the insulation requirements of J6D9.

Applications

J8D4 does not apply to a Class 2 building and a Class 4 part of a building.

Not in NCC 2025. No NSW J8D4 in NCC 2025 Volume One.

The national clause