Specification clause · NCC 2022 Volume One

S27C7 Change table

Specification 27 Accessible adult change facilities · NCC 2019: Spec F2.9: 7

Open S27C7 on NCC Online ↗

(1) The change table must be—

permanently installed, with one of the long edges up against a wall and with a retractable safety rail on the opposite side; and

motorised for the purposes of height adjustment; and

height adjustable between 450 mm and 900 mm above finished floor level; and

not less than 700 mm wide; and

not less than 1800 mm long.

(2) The change table must have a maximum safe working load of not less than 180 kg, including when raising or lowering the table.

(3) The change table must not encroach on any required circulation space.

(4) A dispenser for sanitary wipes must be provided.

(5) A shelf not less than 400 mm long and 150 mm wide must be provided.

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One S27C7.