Specification clause · NCC 2022 Volume One
S27C7 Change table
Specification 27 Accessible adult change facilities · NCC 2019: Spec F2.9: 7
(1) The change table must be—
permanently installed, with one of the long edges up against a wall and with a retractable safety rail on the opposite side; and
motorised for the purposes of height adjustment; and
height adjustable between 450 mm and 900 mm above finished floor level; and
not less than 700 mm wide; and
not less than 1800 mm long.
(2) The change table must have a maximum safe working load of not less than 180 kg, including when raising or lowering the table.
(3) The change table must not encroach on any required circulation space.
(4) A dispenser for sanitary wipes must be provided.
(5) A shelf not less than 400 mm long and 150 mm wide must be provided.
Same wording in NCC 2025 Volume One. See NCC 2025 Volume One S27C7.