S28C9 Acceptable forms of construction for floors — autoclaved aerated concrete
Specification 28 Sound insulation for building elements · NCC 2019: Spec F5.2: Table 3
(1) An acceptable form of construction for autoclaved aerated concrete floors is set out in (2).
(2) 75 mm thick autoclaved aerated concrete floor panel with—
8 mm ceramic tiles with flexible adhesive and waterproof membrane, located above the slab; and
timber joists at 600 mm centres; and
R1.5 glass wool insulation positioned between timber joists; and
28 mm metal furring channels and resilient mounts fixed to underside of joists; and
two layers of 13 mm plasterboard fixed to furring channels,
has an Rw + Ctr of not less than 50, an Ln,w of not more than 62 and an Rw of not less than 50, if constructed as shown in Figure S28C9.
Figure S28C9 75 mm thick autoclaved aerated concrete floor panel