S37C6 Solar admittance — Method 2 (Multiple Aspects)
Specification 37 Calculation of U-Value and solar admittance · NCC 2019: Spec J1.5a: 6
(1) The solar admittance of wall-glazing construction must achieve a representative air-conditioning energy value less than that achieved by the reference solar admittance, when using the following formula:
[formula] (2) In the formula at (1)—
[formula] = the representative air-conditioning energy value; and
[formula] = the area of the wall-glazing construction facing each aspect; and
[formula] = the solar admittance weighting coefficient of each aspect equal to—
where the glazing area on an aspect is less than 20% of the wall-glazing construction area, 0; and
the values in Table S37C6a and Table S37C6b; and
[formula] = the wall-glazing construction solar admittance of each aspect—
equal to the applicable value in J4D6(5) in the reference case; and
calculated in accordance with S37C5(1) in the proposed case.
Table S37C6a Solar admittance weighting coefficient — Class 2 common area, Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area
Aspect
Climate zone 1
Climate zone 2
Climate zone 3
Climate zone 4
Climate zone 5
Climate zone 6
Climate zone 7
Climate zone 8
Northern
1.47
1.95
1.95
2.05
2.28
2.12
2.40
1.88
Southern
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Eastern
1.39
1.58
1.63
1.72
1.72
1.62
1.84
1.92
Western
1.41
1.68
1.65
1.69
1.75
1.67
1.92
1.25
Table S37C6b Solar admittance weighting coefficient — Class 3 or 9c building or Class 9a ward area
Aspect
Climate zone 1
Climate zone 2
Climate zone 3
Climate zone 4
Climate zone 5
Climate zone 6
Climate zone 7
Climate zone 8
Northern
1.42
1.77
1.72
1.55
1.88
1.52
1.60
1.24
Southern
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
Eastern
1.30
1.49
1.48
1.37
1.48
1.28
1.35
1.26
Western
1.37
1.54
1.50
1.36
1.52
1.33
1.40
1.05
Tables
- Table S37C6a Solar admittance weighting coefficient — Class 2 common area, Class 5, 6, 7, 8 or 9b building or Class 9a building other than a ward area
- Table S37C6b Solar admittance weighting coefficient — Class 3 or 9c building or Class 9a ward area
Changed in NCC 2025. See NCC 2025 Volume One S37C6, or show what changed.
(1) The solar admittance of wall-glazing construction must achieve a … the proposed case. Table S37C6a Solar admittance weighting coefficient — Class 2 common area, Class 5, 6, 7, 8 or 9b building or Class … 1.26 Western 1.37 1.54 1.50 1.36 1.52 1.33 1.40 1.05