South Australia variation · NCC 2022 Volume One
SA F1D6 Damp-proofing
Part F1 Surface water management, rising damp and external waterproofing · varies F1D6 Damp-proofing
Delete subclause F1D6(2) and insert SA F1D6(2) as follows:
(2) Damp-proof courses must exhibit long term resistance to degradation by dissolved salts in groundwater and consist of—
embossed black polyethylene film meeting the requirements of clause 7.6 of AS/NZS 2904; or
polyethylene coated aluminium meeting the requirements of clause 7.4 of AS/NZS 2904; or
bitumen impregnated materials of not less than 2.5 mm thickness, meeting the requirements of clause 7.5 of AS/NZS 2904, when used in walls not higher than 7.8 m above the level of the damp-proof course.
Not in NCC 2025. No SA F1D6 in NCC 2025 Volume One.