NCC 2022 Volume One
Specification 38 Spandrel panel thermal performance
4 clauses · Open on NCC Online ↗
- S38C1 ScopeThis Specification describes methods of determining the thermal performance of spandrel panels.
- Table S38C2 Achieved Total R-Value of spandrel panelsType | No insulation | R0.5 insulation | R1.0 insulation | R1.5 insulation | R2.0 insulation Configuration 1 | 0.3 | 0.39 | 0.42 | 0.44 | 0.45…
- S38C2 Spandrel panel R-Value: Calculation method 1Spandrel panels are deemed to have the thermal properties nominated in Table S38C2, where— Configuration 1 consists of— a thermally unbroken…
- S38C3 Spandrel panel R-Value: Calculation method 2The Total system U-Value of a spandrel panel is determined in accordance with the following formula: [formula] (2) In the formula at (1)— [formula]…