S38C2 Spandrel panel R-Value: Calculation method 1
Specification 38 Spandrel panel thermal performance · NCC 2019: Spec J1.5b: 2
Spandrel panels are deemed to have the thermal properties nominated in Table S38C2, where—
Configuration 1 consists of—
a thermally unbroken (bridged) frame; and
a centre of spandrel panel consisting of—
a single-glazed opaque or clear face; and
a 100 mm air gap; and
a 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and
Configuration 2 consists of—
a thermally unbroken (bridged) frame; and
a centre of spandrel panel consisting of—
a double-glazed opaque face; and
a 50 mm air gap; and
a 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and
Configuration 3 consists of—
a thermally broken (unbridged) frame; and
a centre of spandrel panel consisting of—
a double-glazed clear face; and
a 50 mm air gap; and
a 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan; and
Configuration 4 consists of—
a thermally broken (unbridged) frame; and
a centre of spandrel panel consisting of—
a double-glazed low-e clear face; and
a 50 mm air gap; and
a 3 mm aluminium, 0.8 mm galvanised steel or zinc back pan.
Table S38C2 Achieved Total R-Value of spandrel panels
Type
No insulation
R0.5 insulation
R1.0 insulation
R1.5 insulation
R2.0 insulation
Configuration 1
0.3
0.39
0.42
0.44
0.45
Configuration 2
0.35
0.41
0.43
0.44
0.45
Configuration 3
0.84
0.96
1.03
1.07
1.09
Configuration 4
0.91
1.00
1.05
1.09
1.11