Table · NCC 2022 Volume One

Table F4D4d Sanitary facilities in Class 6 buildings – restaurants, cafes, bars

Part F4 Sanitary and other facilities

Open Table F4D4d on NCC Online ↗
User groupFacility typeDesign occupancyNumber
Male patronsCloset pans1 - 1001
101 - 3002
>300Add 1 per 200
Urinals1 - 501
51 - 1002
101 - 1503
151 - 2004
201 - 2505
>250Add 1 per 100
Washbasins1 - 501
51 - 2002
>200Add 1 per 200
Female patronsCloset pans1 - 251
26 - 502
51 - 1003
101 - 1504
151 - 2005
201 - 2506
>250Add 1 per 100
Washbasins1 - 501
51 - 1502
>150Add 1 per 200

Table Notes

Sanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.

Table for F4D4 Facilities in Class 3 to 9 buildings

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table F4D4d.