Table · NCC 2022 Volume One

Table F4D4j Sanitary facilities in Class 9b buildings – sports venues or the like

Part F4 Sanitary and other facilities

Open Table F4D4j on NCC Online ↗
User groupFacility typeDesign occupancyNumber
Male participantsCloset pans1 - 201
>20Add 1 per 20
Urinals1 - 101
>10Add 1 per 10
Washbasins1 - 101
>10Add 1 per 10
Female participantsCloset pans1 - 101
>10Add 1 per 10
Washbasins1 - 101
>10Add 1 per 10
Male spectators or patronsCloset pans1 - 2501
251 - 5002
>500Add 1 per 500
Urinals1 - 1001
>100Add 1 per 100
Washbasins1 - 1501
>150Add 1 per 150
Female spectators or patronsCloset pans1 - 151
16 - 602
61 - 1203
>120Add 1 per 70
Washbasins1 - 601
61 - 2002
201 - 3503
>350Add 1 per 150

Table for F4D4 Facilities in Class 3 to 9 buildings

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table F4D4j.