Table · NCC 2025 Volume One
Table F4D4j Sanitary facilities in Class 9b buildings – sports venues or the like
Part F4 Sanitary and other facilities
| User group | Facility type | Design occupancy | Number |
|---|---|---|---|
| Male participants | Closet pans | 1 - 20 | 1 |
| >20 | Add 1 per 20 | ||
| Urinals | 1 - 10 | 1 | |
| >10 | Add 1 per 10 | ||
| Washbasins | 1 - 10 | 1 | |
| >10 | Add 1 per 10 | ||
| Female participants | Closet pans | 1 - 10 | 1 |
| >10 | Add 1 per 10 | ||
| Washbasins | 1 - 10 | 1 | |
| >10 | Add 1 per 10 | ||
| Male spectators or patrons | Closet pans | 1 - 250 | 1 |
| 251 - 500 | 2 | ||
| >500 | Add 1 per 500 | ||
| Urinals | 1 - 100 | 1 | |
| >100 | Add 1 per 100 | ||
| Washbasins | 1 - 150 | 1 | |
| >150 | Add 1 per 150 | ||
| Female spectators or patrons | Closet pans | 1 - 15 | 1 |
| 16 - 60 | 2 | ||
| 61 - 120 | 3 | ||
| >120 | Add 1 per 70 | ||
| Washbasins | 1 - 60 | 1 | |
| 61 - 200 | 2 | ||
| 201 - 350 | 3 | ||
| >350 | Add 1 per 150 |
Table for F4D4 Facilities in Class 3 to 9 buildings
Same wording in NCC 2022 Volume One. See NCC 2022 Volume One Table F4D4j.