Table F4D4l Sanitary facilities in Class 9b buildings – public halls, function rooms or the like

Part F4 Sanitary and other facilities

Open Table F4D4l on NCC Online ↗
User groupFacility typeDesign occupancyNumber
Male patronsCloset pans1 - 1001
>100Add 1 per 200
Urinals1 - 501
51 - 1002
101 - 1503
151 - 2004
201 - 2505
>250Add 1 per 100
Washbasins1 - 501
51 - 2002
>200Add 1 per 200
Female patronsCloset pans1 - 251
26 - 502
51 - 1003
101 - 1504
151 - 2005
201 - 2506
>250Add 1 per 100
Washbasins1 - 501
51 - 1502
>150Add 1 per 200

Table Notes

Sanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.

Table for F4D4 Facilities in Class 3 to 9 buildings

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table F4D4l.