Table · NCC 2022 Volume One

Table J3D12j Conductance factors — climate zones 2 to 7

Part J3 Elemental provisions for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Open Table J3D12j on NCC Online ↗
Type of factorClimate zone 2Climate zone 3Climate zone 4Climate zone 5Climate zone 6Climate zone 7
Room type multiplier (for bedroom and unconditioned areas) (RS)0.400.560.710.910.871.11
Frame solar absorptance multiplier (for metal frame windows) (FS) SA ≤ 0.401.000.890.870.850.740.86
Frame solar absorptance multiplier (for metal frame windows) (FS) SA > 0.40 to < 0.681.061.001.001.001.001.00
Frame solar absorptance multiplier (for metal frame windows) (FS) SA ≥ 0.681.221.181.221.241.221.32
Floor factor for tiled or vinyl covered floors (HS)1.061.061.131.131.041.21
Floor factor for other than tiled or vinyl covered floors (HS)0.970.970.940.940.940.90

Table Notes

Interpolation is allowed for values between those shown.

Table for J3D12 External summer glazing of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Same wording in NCC 2025 Volume One. See NCC 2025 Volume One Table J3D12j.

Defined terms used