Table J7D3c Illumination power density adjustment factor for light colour
Part J7 Artificial lighting and power
| Light source | Description | Illumination power density adjustment factor |
|---|---|---|
| CRI ≥ 90 | Where lighting with good colour rendering is used | 0.9 |
| CCT ≤ 3500 K Note | Where lighting with a warm appearance is used | 0.8 |
| CCT ≥ 4500 K | Where lighting with a cool appearance is used | 1.1 |
Table Notes
Includes luminaires that can adjust their CCT to 3500 K or below.
Table for J7D3 Artificial lighting