Table · NCC 2022 Volume One

Table S34C3 Greenhouse gas emissions factors (kgCO2-e/GJ)

Specification 34 Modelling parameters for J1V3

Open Table S34C3 on NCC Online ↗
Energy SourceACTNSWNTQLDSATASVICWA
Electricity-23616225410144279191
Gas-51.5351.5351.5351.5351.5351.5351.53

Table Notes

National emissions factors are not applicable to calculations for buildings in the ACT as they do not take into account investments in renewable electricity generation in the national electricity market made by the ACT.

Values for the ACT can be found in the ACT Appendix.

Table for S34C3 Proposed building and reference building

Changed in NCC 2025. See NCC 2025 Volume One Table S34C3, or show what changed.

Energy Source | ACT | NSW | NT | QLD | SA | TAS | VIC | WA Electricity | - | 236 51 | 162 110 | 254 120 | 101 22.5 | 44 9 | 279 135 | 191 83 Gas | - | 51.53 | 51.53 | 51.53 | … for the ACT can be found in the ACT Appendix.

Removed words are struck through; added words are highlighted. Comparison of the text only.