Table · NCC 2022 Volume One

Table S45C3d Internal heat loads for lighting, cooking and appliances

Specification 45 Modelling profiles for J1V5

Open Table S45C3d on NCC Online ↗
Sole-occupancy unit area (excluding garage) (m2)Occupancy (m2/person)Day time lighting power density (6:00 am to 6:00 pm) (W/m2)Night-time lighting power density (6:00 pm to 6:00 am) (W/m2)Cooking in kitchen zone only (W/m2 kitchen area)Appliances (except oven) in whole sole-occupancy unit (W/m2)
≤ 10041.24.04.036.24.38
> 100 to ≤ 12544.34.04.034.73.52
> 125 to ≤ 15047.84.04.028.92.99
> 150 to ≤ 17551.74.04.024.82.60
> 175 to ≤ 20055.84.04.025.32.26
> 200 to ≤ 22560.04.04.022.52.02
> 225 to ≤ 25064.44.04.020.21.84
> 250 to ≤ 27568.94.04.018.41.68
> 275 to ≤ 30073.34.04.016.91.55
> 300 to ≤ 32577.54.04.015.61.44
> 325 to ≤ 35081.64.04.014.51.34
> 350 to ≤ 37585.44.04.013.51.26
> 37589.04.04.012.71.19

Table for S45C3 Proposed building and reference building

Not in NCC 2025. No Table S45C3d in NCC 2025 Volume One.

Defined terms used