Tasmania variation · NCC 2022 Volume One
TAS I18D5 Ventilation
TAS Part I18 Temporary structures
(1) Natural ventilation or mechanical ventilation must be provided to all enclosed areas in a temporary structure.
(2) Natural ventilation must as far as practicable consist of openings or devices which can be opened with an aggregate opening of not less than 5% of the floor area of the enclosed area.
(3) Mechanical ventilation must as far as practicable comply with the relevant provisions of AS 1668.2.
Changed in NCC 2025. See NCC 2025 Volume One TAS I18D5, or show what changed.
Delete clause I18D5 and insert TAS I18D5 as follows: (1) Natural ventilation or mechanical ventilation must be provided to … as practicable comply with the relevant provisions of AS 1668.2.
Removed words are struck through; added words are highlighted. Comparison of the text only.