NCC 2022 Volume One
Tasmania variations
140 TAS variations to NCC 2022 Volume One: clauses replaced, added or deleted in Tasmania. Search with TAS variations.
- TAS A1G4 InterpretationInsert TAS subclause A1G4(7) in clause A1G4 as follows: (7) The Director of Building Control may issue written advice to deal with arising issues…
- TAS A5G4 Evidence of suitability ─ Volume Three (PCA)Insert TAS subclause A5G4(7) in clause A5G4 as follows: (7) A product used in roof plumbing, heating ventilation and air-conditioning or on-site…
- TAS D1P10 Standards made under the Disability Discrimination ActInsert TAS clause D1P10 in clause D1P10 as follows: A building or part of a building must be accessible in accordance with the requirements of a…
- TAS D4D1 Deemed-to-Satisfy ProvisionsDelete subclause D4D1(1) and insert TAS D4D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements D1P1 to…
- TAS D4D5 ExemptionsDelete clause D4D5 and insert TAS D4D5 as follows: The following areas are not required to be accessible: An area where access would be…
- TAS D4D14 Compliance with Premises StandardsInsert TAS clause D4D14 in clause D4D14 as follows: (1) A building solution must comply with the Disability (Access to Premises - Buildings)…
- TAS E1D1 Deemed-to-Satisfy ProvisionsDelete clause E1D1 and insert TAS E1D1 as follows: Performance RequirementsE1P1 to E1P6 and TAS E1P7 are satisfied by complying with E1D2 to E1D16,…
- TAS E1D17 Fire detection and alarm systemInsert TAS clause E1D17 in clause E1D17 as follows: An automatic fire detection and alarm system must comply with S20C4 and S20C8.
- TAS E1P7 Automatic fire detection systemInsert TAS clause E1P7 in clause E1P7 as follows: An automatic fire detection system must be installed to the degree necessary to alert the fire…
- TAS F4D13 Non-flushed urinalsInsert TAS clause F4D13 in clause F4D13 as follows: Non-flushed urinals not connected to a sewerage system must comply with TAS F4D14.
- TAS F4D14 Installation of closet fixturesInsert TAS clause F4D14 in clause F4D14 as follows: (1) If a sufficient sewerage system is not available, an authorised alternative means of…
- TAS F8P1 Condensation and water vapour managementDelete clause F8P1 and insert TAS F8P1 as follows: In a sole-occupancy unit of a Class 2 building or a Class 4 part of a building, risks associated…
- TAS G1D1 Deemed-to-Satisfy ProvisionsDelete subclause G1D1(2) and insert TAS G1D1(2) as follows: (2) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements G1P2 to…
- TAS G1D2 Swimming poolsDelete clause G1D2 and insert TAS G1D2 as follows: (1) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2…
- TAS G1P2 Swimming pool access and water recirculation systemsDelete clause G1P2 and insert TAS G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be continuous for the full extent of…
- TAS G1P6 Swimming poolsInsert TAS clause G1P6 in clause G1P6 as follows: Swimming pools must be suitable and safe to use and be provided with appropriate facilities.…
- TAS G5P1 Bushfire resistanceDelete clause G5P1 and insert TAS G5P1 as follows: A building that is constructed in a designated bushfire prone area must be designed and…
- TAS G5P2 Additional bushfire requirements for certain Class 9 buildingsDelete clause G5P2 and insert TAS G5P2 as follows: A building that is constructed in a designated bushfire prone area and occupied by people who may…
- TAS I4D1 Application of PartThis Part applies to any premises where food intended for human consumption is manufactured, processed or sold and to which the following apply—…
- TAS I4D2 Deemed-to-Satisfy ProvisionsPerformance RequirementsTAS I4P1 to TAS I4P13 are satisfied by complying with the relevant provisions of TAS I4D3 to TAS I4D18.
- TAS I4D3 General requirementsThe provision of— close-fitting windows and doors; and air intakes that do not draw in contaminated air; and air locks and self-closing doors to…
- TAS I4D4 Pests and contaminantsPremises where customers are served outside the premises through an opening, that has an appliance for the elimination of flies and mechanical…
- TAS I4D5 Drains and pipesPremises satisfy TAS I4P4 where— a grease trap, an overflow (relief) gully or an untrapped opening connected directly with a drain or sewer, is not…
- TAS I4D6 Offensive material and trade wasteWhere offensive material or trade waste is stored, a separate area or room which— is paved and easily cleanable; and is graded to drain to a…
- TAS I4D7 VentilationA mechanical ventilating exhaust system complying with the requirements of AS/NZS 1668.1 and AS 1668.2 satisfies TAS I4P6.
- TAS I4D8 LightingA lighting system that— complies with AS 1680.1 and AS/NZS 1680.2.4; and in areas where open food is handled or stored, has light fittings which…
- TAS I4D9 Floors, walls and ceilingsFloors, walls and ceilings constructed in accordance with Section 3 of AS 4674, satisfy TAS I4P8 and TAS I4P9. (2) The wall and ceiling provisions…
- TAS I4D10 Separation of work placeA room where food for sale is processed, manufactured, prepared, deposited, treated, stored or packed, that does not have direct communication with…
- TAS I4D11 WashbasinsPremises or places for preparation or storage of food for sale provided with not less than one washbasin complying with (2) within five metres of…
- TAS I4D12 SinksWhere equipment and utensils are required to be manually cleaned and sanitised, or food preparation requires a sink, premises that are provided with…
- TAS I4D13 Design, construction and installation of fixtures, fittings and equipmentThe provision of fixtures, fittings and equipment designed, constructed and installed in accordance with clause 4.2 and clause 4.3 of AS 4674…
- TAS I4D14 Storage of materials and equipmentSeparate areas for the storage of fuel, cleaning compounds and general maintenance equipment provided so as to prevent contamination of the product…
- TAS I4D15 Food storeAn eating house provided with a dry-food store, satisfies TAS I4P12.
- TAS I4D16 Meat premisesPremises used for the preparation or sale of red meat, other than those licensed under the Primary Produce Safety Act 2011, that comply with— TAS…
- TAS I4D17 Dairy produceDefinition: Dairy produce products include milk, colostrum, liquid milk products, cream and thickened cream, butter, butter concentrate, buttermilk,…
- TAS I4D18 Refrigerated and cooling chambersThe construction of a refrigerated chamber or cooling chamber installed in premises for storage of food complying with the requirements for that…
- TAS I4F1 Food premisesEach building or part of a building constructed as a food premise must be able to be used in such a manner that minimises opportunities for food…
- TAS I4O1 ObjectiveThe objective of this Part is to facilitate the safe manufacture, preparation, storage and packing of food for sale for human consumption.
- TAS I4P1 Application of PartTAS I4P2 to TAS I4P13 applies to any premises where food intended for human consumption is manufactured, processed, prepared, packed, stored or sold…
- TAS I4P2 Design and constructionThe design and construction of food premises must— be appropriate for the activities for which the premises are used; and provide adequate space for…
- TAS I4P3 Water supplyFood premises must have an adequate supply of water if water is to be used at the food premises for any of the activities conducted on the food…
- TAS I4P4 Sewage and waste water disposalFood premises must have a sewage and waste water disposal system that— will effectively dispose of all sewage and waste water; and is constructed…
- TAS I4P5 Storage of garbage and recyclablesFood premises must have facilities for the storage of garbage and recyclable matter that— adequately contain the volume and type of garbage and…
- TAS I4P6 VentilationFood premises must have sufficient natural or mechanical ventilation to remove fumes, smoke and vapours from the food premises.
- TAS I4P7 LightingFood premises must have lighting systems that provide sufficient natural or artificial light for the activities conducted on the food premises.
- TAS I4P8 FloorsFloors must be designed and constructed in a way that is appropriate for the activities conducted on the food premises. (2) Floors must— be able to…
- TAS I4P9 Walls and ceilingsWalls and ceilings— must be designed and constructed in a way that is appropriate for the activities conducted on the food premises; and must be…
- TAS I4P10 Hand washing facilitiesFood premises must have hand washing facilities that are located where they can be easily accessed by food handlers— within areas where food…
- TAS I4P11 Fixtures, fittings and equipmentFixtures, fittings and equipment must— be adequate for the production of wholesome food; and be fit for their intended use; and be designed,…
- TAS I4P12 Storage facilitiesFood premises must have adequate storage facilities— for the storage of items that are likely to be the source of contamination of food, including…
- TAS I4P13 Refrigerated and cooling chambersAll refrigerated and cooling chambers must be constructed so that the stored products will not be contaminated.
- TAS I5D1 Application of PartThis Part applies to all dining rooms and bar rooms (excluding bar service areas) on licensed premises covered by the Liquor Licensing Act 1990. (2)…
- TAS I5D2 Sanitary facilitiesSeparate sanitary facilities for male sand females must be provided in close proximity to each dining room and bar room in licensed premises. (2)…
- TAS I5D3 Separation from other areasA dining room must not have a direct opening to living quarters, a laundry, bathroom or garage or a room where animals are housed.
- TAS I6D1 Application of PartThis Part is applicable to— meat premises processing animals, including game and poultry, and producing meat and meat products for human…
- TAS I6D2 Premises processing animals and meatPremises used for the processing of animals and meat for human consumption must comply with the relevant Parts and Sections of the Australian…
- TAS I7D1 Application of PartThis Part is applicable to every farm dairy as covered by the Dairy Industry Act 1994. (2) Dairies must be constructed in such a manner that…
- TAS I7D2 Milking sheds and holding yardsThe walls (including the walls of a pit of a herringbone design milking shed) must be non-absorbent and easy to clean. (2) The floor of a holding…
- TAS I7D3 Milk receiving area and milk storage roomA Milk Receiving Area and Milk Storage Room must— have internal surfaces that are smooth, non-absorbent, free-draining and easy to clean; and be…
- TAS I7D4 Water supplyAn adequate and suitable supply of water must be available for plant sanitation, teat washing, milk cooling and vat rinsing.
- TAS I8D1 Application of PartThis Part applies to all pharmacy business premises registered under the Pharmacy Control Act. (2) Pharmacies must be able to be secured against…
- TAS I8D2 DefinitionIn this Part the term “dispensary” means the room or area within a pharmacy or other premises which a registered pharmaceutical chemist uses for the…
- TAS I8D3 Pharmacy premisesEach premises used as a pharmacy must have— a dispensary for the compounding or dispensing of drugs and for the storage of material used in…
- TAS I8D4 DispensaryA dispensary must be located— within a pharmacy in a position to enable a person in the dispensary to supervise the dispensary, storage areas for…
- TAS I8D5 Security of dispensaryEvery dispensary and enclosure set aside for the storage of narcotic substances and poisons must be able to be secured against entry. (2) If a…
- TAS I9D1 Application of PartThis Part applies to health service establishments as defined in the Health Service Establishment Act 2006 including— a day procedure centre; or a…
- TAS I9D2 Design and construction of health service establishmentsEvery health service establishment must be constructed and maintained in accordance with the Australasian Health Facility Guidelines.
- TAS I10D1 Application of PartThis Part applies to any premises used for the storage or preparation for burial, cremation or disposal by other means, of bodies of deceased…
- TAS I10D2 Layout of mortuaryA mortuary may be integral with the remainder of a building but must be separated physically from all public areas of that building. (2) Each…
- TAS I10D3 Construction of body preparation roomThe floor must be— of impervious material with a smooth, unbroken surface; and uniformly graded to a floor drain. (2) All walls and partitions must…
- TAS I10D4 Water supply and sewerageEach mortuary with a body preparation room must be connected to— a permanent water supply with a physical discontinuity, provided by a registered…
- TAS I11D1 Application of PartThis Part is applicable to every building or premises on which foundry operations are undertaken. (2) Foundries must provide for the comfort and…
- TAS I11D2 GeneralEvery floor in a foundry must be level and, in places other than where molten metal is poured, must be composed or similar material or wooden…
- TAS I11D3 Cupola charging platformThe floors of cupola charging platforms must be— of heavy timber or non-slip steel plate; and securely fixed in position; and level. (2) All parts…
- TAS I11D4 Deep moulds and pitsDeep moulds or pits, for permanent use— must be lined with bricks, concrete, or other suitable material in such a manner as to provide adequate…
- TAS I11D5 Pot furnacesWhere pot furnaces are below ground level, the pit must be covered by a substantial grating at the point at which metal is removed from the furnace,…
- TAS I11D6 Hand laminating and spray depositingThe walls and floors of areas to be used for hand laminating and spray depositing must be constructed of non-combustible materials.
- TAS I12D1 Application of PartThis Part is applicable to every building in which glass reinforced plastics are manufactured or processed. (2) Premises for manufacture or…
- TAS I12D2 Separation from other buildingsA building for the manufacture or processing of glass reinforced plastics must be— separated from other buildings or parts of an occupancy by means…
- TAS I12D3 Rise in storeysThe building must be of single storey construction.
- TAS I12D4 Maximum floor areasThe floor area of any building or fire-separated section must not exceed the relevant maximum floor area set out in Table TAS I12D4. Insert TAS…
- TAS I12D5 Required exitsEach fire-separated section of a building which is a work place must have at least two exits for escape purposes and the number and location of…
- TAS I12D7 VentilationMechanical or natural ventilation must be via low-level, exhaust ducting in a wall and a fixed, open, floor-level, fresh-air inlet ducting in the…
- TAS I12D8 Smoke and heat roof ventsEach fire-separated section must be provided with automatic smoke and heat roof vents.
- TAS I13D1 Application of PartThis Part is applicable to every building in which isocyanate production or processing is undertaken. (2) Premises for production or processing of…
- TAS I13D2 Areas of work placesWork places in which an isocyanate industry is carried out must be divided into the following divisional areas: Administration and staff amenities.…
- TAS I13D3 Separation from other areas and buildingsEach of the divisional areas required by TAS I13D2 other than the administration and staff amenities building, must be— separated from each of the…
- TAS I13D4 Rise in storeysThe building must be of single storey construction.
- TAS I13D5 Maximum floor areasThe floor area of any building or fire-separated section must not exceed the area shown in Table TAS I12D4.
- TAS I13D6 Required exitsEvery building and divisional area of a work place must have not less than 2 exits for escape purposes. (2) The number and location of the exits…
- TAS I13D7 Bulk stores for polyols and isocyanatesA bulk store for polyols must be constructed from non-combustible materials and have a smooth impervious concrete floor and it must protect the…
- TAS I13D8 Curing roomThe curing room for the storage of newly produced flexible polyurethane foam must be constructed of non-combustible materials with a smooth…
- TAS I14D1 Application of PartThis Part is applicable to every building where any of the processes of electro-plating, electro-polishing, anodising or etching are undertaken. (2)…
- TAS I14D2 FloorsThe floor of every plating area must be— so graded as to— permit easy flushing with water; and prevent liquids from flowing from the area into other…
- TAS I14D3 Height of plating areaEvery part of a plating area must be not less than 2.7 m in height— measured from the floor to the ceiling if a ceiling is provided; or measured…
- TAS I14D4 Air spaceIn every plating area there must be not less than 14 m3 of air space for each person employed and, in the calculation of such space, the height…
- TAS I14D5 Ceiling constructionThe ceiling of a plating area must be so constructed as to prevent, so far as is practicable, atmospheric contaminants from escaping into rooms or…
- TAS I15D1 Application of PartThis Part is applicable to every building in which lead processes are used. (2) Premises used for lead processing must— provide for the safety and…
- TAS I15D2 FloorsThe floor of every work place where a lead process is used must be— so constructed of concrete or other suitable material as to be smooth and…
- TAS I15D3 Height of lead processing areasEvery part of a lead processing area must be not less than 2.7 m in height— where a ceiling is provided, measured from the floor to the ceiling; or…
- TAS I15D4 Air space and floor spaceIn every lead processing area there must be not less than 14 m3 of air space for each person employed therein, and in the calculation of such space…
- TAS I15D5 Interior of lead processing areasThe inner surfaces of the walls of every lead processing area must be of a smooth material impervious to fluids and must not contain any projections…
- TAS I15D6 Dust collectionAny areas in which dust-forming lead particles are manipulated, moved or treated must be served by a mechanical exhaust ventilation system capable…
- TAS I15D7 Isolation of certain processesWhere any process of pasting of electric accumulator plates or drying of paste plates, or melting down of pasted plates or of formation with tacking…
- TAS I15D8 Drying room shelvesThe racks or shelves provided in any drying room must be not more than 2.6 m from the floor nor more than 650 mm in width except that, in the case…
- TAS I15D9 Washing facilitiesWashing facilities served with running hot and cold water for the use of all employees engaged in a lead process must be provided consisting of— one…
- TAS I15D10 Change roomsIn every work place in which lead is processed there must be provided two suitable furnished change rooms for the use of employees as follows— one…
- TAS I16D1 Application of PartThis Part applies to early childhood centres and school age care facilities approved under the Education and Care Services National Law…
- TAS I16D2 Deemed-to-Satisfy ProvisionsPerformance RequirementTAS I16P1 is satisfied by complying with the relevant provisions of the Early Childhood Centre and School Age Care Facilities…
- TAS I16F1 Early childhood centres and school age care facilitiesAn early childhood centre and school age care facility must be designed and constructed to provide a safe environment and provide for the health,…
- TAS I16O1 ObjectiveThe Objective of this Part is to regulate the physical specification of early childhood centres and school age care facilities at which education…
- TAS I16P1 Design and constructionThe design and construction of an early childhood centre and school age care facility must to the degree necessary, provide an environment that is…
- TAS I16P2 Health and amenityAn early childhood centre and school age care facility, must to the degree necessary, have sufficient space and facilities to ensure a healthy, safe…
- TAS I16P3 Perimeter fencing and barriersAn early childhood centre and school age care facility must to the degree necessary, have fencing around the perimeter of any outdoor play space,…
- TAS I17D1 Application of PartThis Part is applicable to every building where work is undertaken on gas-fuelled vehicles.
- TAS I17D2 Working areasThe working area of a building where work is undertaken on a gas-fuelled vehicle is to be designed and constructed to comply with the requirements…
- TAS I18D1 Application of PartThis Part only applies to a temporary structure that— is used by the public as a place of assembly as described in the Public Health Act 1997; and…
- TAS I18D2 Deemed-to-Satisfy ProvisionsPerformance RequirementsTAS I18P1 to TAS I18P16 are satisfied by complying with the provisions of the ABCB Temporary Structures Standard, except for…
- TAS I18D3 AccessAccess for people with disabilities must be provided to and within a temporary structure by means of a continuous path of travel. (2) Access for…
- TAS I18D4 LightingNatural or artificial lighting must be provided to all enclosed areas in a temporary structure. (2) Natural lighting must as far as practicable be…
- TAS I18D5 VentilationNatural ventilation or mechanical ventilation must be provided to all enclosed areas in a temporary structure. (2) Natural ventilation must as far…
- TAS I18D6 ElectricalAll electrical installations in a temporary structure must be installed in accordance with AS/NZS 3000.
- TAS I18D7 Heating appliancesThe installation of a stove, heater or similar appliance in a temporary structure must as far as practicable comply with the following standards:…
- TAS I18P1 Application of PartTAS I18P2 to TAS I18P16 only apply to a temporary structure that— is used by the public as a place of assembly as described in the Public Health Act…
- TAS I18P2 Safety and serviceabilityA temporary structure must, to the degree necessary, be capable of sustaining at an acceptable level of safety and serviceability the most adverse…
- TAS I18P3 Resistance to the spread of fireThe material used in a temporary structure must, to the degree necessary, be capable of resisting the spread of fire to limit the generation of…
- TAS I18P4 AccessAccess must be provided, to the degree necessary, to enable safe, equitable and dignified movement of people to and within a temporary structure.…
- TAS I18P5 ExitsExits must be provided to the degree necessary, from a temporary structure to enable the safe evacuation of occupants, with their number, location…
- TAS I18P6 Fall preventionWhere a person could fall 1 m or more, due to a sudden change of level within or associated with a temporary structure, a barrier must to the degree…
- TAS I18P7 LightingA level of illumination for safe evacuation from a temporary structure in an emergency must be provided, to the degree necessary, appropriate to…
- TAS I18P8 Identification of exitsTo facilitate evacuation from a temporary structure suitable signs or other means of identification must, to the degree necessary— be provided to…
- TAS I18P9 Fire-fighting equipmentFire equipment must be installed in a temporary structure to the degree necessary, to allow the occupants to undertake initial attack on a fire…
- TAS I18P10 Sanitary facilitiesSanitary facilities for personal hygiene must be provided in a convenient location associated with a temporary structure, to the degree necessary,…
- TAS I18P11 Artificial lightingA temporary structure must be provided with natural or artificial lighting to enable the safe use and movement of people using the structure. (2)…
- TAS I18P12 VentilationA temporary structure must be provided with a means of ventilation which will maintain adequate air quality. (2) Ventilation must be provided to the…
- TAS I18P13 Electrical servicesElectrical services must be installed to the degree necessary, to provide a level of safety appropriate to the environment and function or use of a…
- TAS I18P14 Heating appliancesWhere provided for a temporary structure, a heating appliance and its associated components must be installed to the degree necessary— to withstand…
- TAS I18P15 Tiered seatingA temporary structure of tiered seating must be designed and constructed to the degree necessary, to provide for the safety of occupants and orderly…
- TAS I18P16 Safe environmentA temporary structure must, to the degree necessary, be a safe and hazard free environment for the people using the structure.
- TAS Part J3 Elemental provisions for a sole-occupancy unit of a Class 2 building or a Class 4 part of a buildingThis Part is deleted from the BCA in Tasmania. In Tasmania, for a Class 2 building and Class 4 part of a building, Section J is replaced with…