Tasmania variation · NCC 2022 Volume One

TAS I4D3 General requirements

TAS Part I4 Food premises

Open on NCC Online ↗

(1) The provision of—

close-fitting windows and doors; and

air intakes that do not draw in contaminated air; and

air locks and self-closing doors to separate toilet areas, laundries and living areas from food handling areas; and

mechanical ventilation that removes sources of contamination,

satisfies TAS I4P2(d)(i).

(2) The provision of—

self-closing or pest-screened external doors; and

mesh screens at opening windows or other ventilation openings; and

sealing to drains, grease traps and ventilation pipes; and

sealing to openings where pipes pass through external walls; and

the installation of pest-proof flashings to doors,

satisfies TAS I4P2(d)(ii).

(3) The provision of—

vermin-proof sealing; or

filling; or

access for inspection and cleaning of boxed-in areas,

satisfies TAS I4P2(d)(iii).

(4) The provision of a reticulated water supply from—

a regulated entity; or

a private water supply with on-site treatment,

which meets the Australian Drinking Water Guidelines, satisfies TAS I4P3(2).

Notes

‘Regulated entity’ has the same meaning as Water and Sewerage Industry Act 2008.

Changed in NCC 2025. See NCC 2025 Volume One TAS I4D3, or show what changed.

Delete clause I4D3 and insert TAS I4D3 as follows: (1) The provision of — close-fitting windows and doors; and … the same meaning as Water and Sewerage Industry Act 2008.

Removed words are struck through; added words are highlighted. Comparison of the text only.

Other states and territories