TAS I7D2 Milking sheds and holding yards

TAS Part I7 Farm dairy premises

Open on NCC Online ↗

(1) The walls (including the walls of a pit of a herringbone design milking shed) must be non-absorbent and easy to clean.

(2) The floor of a holding yard and a milking shed must be non-absorbent, easy to clean and free-draining.

(3) The lighting of a holding yard and a milking shed must be adequate for proper milking.

(4) The working space in a milking shed is to be sufficient to minimise the risk of contamination of milk during milking.

(5) Effluent from a holding yard and a milking shed is to be drained to a suitable point for disposal.

(6) The requirements of (1), (2) and (3) are satisfied if—

the walls are constructed of well-compacted smooth finish concrete or other material sealed to be impervious to moisture; and

the floors are constructed of well-compacted smooth finish concrete and are graded to a drain; and

joints between wall sections and walls and walls and floors are sealed to prevent entry of water and pests; and

artificial lighting is designed to comply with AS 1680.

Changed in NCC 2025. See NCC 2025 Volume One TAS I7D2, or show what changed.

Delete clause I7D2 and insert TAS I7D2 as follows: (1) The walls (including the walls of a pit of … and artificial lighting is designed to comply with AS 1680.

Removed words are struck through; added words are highlighted. Comparison of the text only.